Bosch d9412gv3 User Manual

Page of 154
D9412GV3/D7412GV3 | Program Entry Guide | 2.0  Panel and Area Wide Parameters 
EN | 83 
 
 
Bosch Security Systems, Inc. | 10/11 | F01U170807-02 
 
2.1.1 User 
Groups 
For the D9412GV3, there are 249 groups (99 groups 
for the D7412GV3) consisting of one user with a 
passcode and token (master) and three users with 
tokens or cards but not a passcode (sub-user). All 
users in the group share the same authority level as 
the master user. 
2.1.2 Passcodes 
In a control panel with factory default settings, only 
the master user has an assigned passcode. A 
passcode can be three to six digits. Entering three 
digits in User ### chooses the user. Programming 
the U001 Passcode assigns a passcode to the 
master user. Sub-users cannot use the passcode. Do 
not assign tokens or cards to User ID 0 (zero), which 
is reserved for the service passcode. 
Passcode Tamper 
If a user enters six consecutive invalid passcodes at 
the same keypad, the control panel sends a User 
Code Tamper report to the central station. The invalid 
passcode count resets when a valid passcode is 
entered at the same keypad. Refer to R# Usr Code 
Tamper in Table 10 on page 21 for information on 
enabling this report. 
The passcode tamper condition is also reported in a 
manually initiated Extended Test Report and to RPS 
through control panel diagnostics. As a result, the 
tamper condition is reset after the successful 
completion of a manual report or when disconnecting 
from an RPS session. The tamper condition is not 
reset when the control panel reboots. 
2.1.3 User 
Group 
Window 
Use U### User Group to enable and disable the 
U### Passcode for up to eight different time periods 
throughout the day. Assign the number (1 to 8) 
programmed in U### User Group to a User 
Windows #
. If the user is outside a window, 
COMMAND DISABLED appears on the keypad after 
the user enters the passcode and presses [ENTER]. 
 
This window does not affect tokens and 
cards. It only affects the passcode of the 
master user. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
When using the Add/Change User 
function at the keypad, the authority levels 
and the changes made affect the master 
user’s passcode and the entire group’s 
token or cards. 
When using the ACCESS CONTROL 
LEVEL function at the keypad, the whole 
group is affected by whether or not the 
level is on or off for access control 
functions only. 
When using the DELETE USER? 
function, the whole group is deleted. You 
cannot delete each user within the group 
individually. Use the ADD/CHG USER? 
function to change a user token or card 
instead of deleting the whole group. 
2.1.4 User 
Name 
Each user group can be assigned one U### Name
This name is logged and sent to the central station 
for all the users in the group. The user ID is used to 
differentiate which user’s token or card was 
executed. 
 
When using a D1260 Keypad, User 249 
text is used for contact information text 
(such as telephone numbers). If a D1260 
is installed on the system, do not use 
User 249 for user ID information. 
2.1.5 Tokens 
and 
Cards 
The master user assigned the passcode can also be 
assigned a token or card by programming the U### 
Mstr Site
 and U### Mstr Crd Data
Three more tokens or cards are assigned to the user 
group for sub-users using the U### SU# Site and 
U### SU# C/D