P## Entry Tone Off 
Default: 
No 
Selection: 
Yes or No 
Yes 
Disables the entry delay tone when 
this perimeter point is faulted.  
This is intended for use with points 
set to P## Type 1 (Perimeter). 
No 
A tone sounds at keypads when this 
point starts entry delay. 
This option enables and disables the entry delay 
warning tone for this point. 
 
Do not set points to No if they are actually 
used to notify the user to disarm the 
system. The possibility of false alarms 
increases if the entry delay warning is not 
used. 
 
 
Entry Tone can also be turned off when 
programming your CC Entry Tone, in 
Section 2.9 Keypad (Command Center) 
on page 50, that allows you to manage 
the tone by keypad. 
 
 
You might want to disable the entry tone 
in high security applications where you do 
not want to annunciate entry delay. 
P## Silent Bell 
Default: 
No 
Selection: 
Yes or No 
Yes 
Activate the Silent Alarm Relay when 
this point enters into alarm. Keypads 
do not sound the alarm tone for Non-
fire points. 
No 
Activate either the Fire Bell relay or 
Alarm Bell relay and sound the alarm 
tone at keypads when this point 
enters into alarm. If this is a Fire 
point, it activates the Fire Bell relay 
programmed in Relay Parameters. 
Otherwise, it activates the Alarm Bell 
relay. The amount of time and 
pattern of the relay activation is 
programmed by area in Bell 
Parameters. 
 
 
To meet UL 864 requirements, set this 
parameter to No
 
 
 
If you want this point to ring the bell 
because the message failed to reach the 
central station receiver, program P## 
Audible After 2 Failures
 as Yes
P## Ring Until Restored 
Default: 
No 
Selection: 
Yes or No 
Yes 
The relay programmed to provide 
fire alarm output for this point cannot 
be de-activated until the point 
restores to normal. 
No 
The relay programmed to provide 
fire alarm output for this point can be 
de-activated before the point 
restores to normal. 
Use this option to determine if the bell continues to 
ring until the Fire Bell time expires. The point returns 
to a normal condition when the user acknowledges 
the alarm to silence the bell. 
 
If the point restores and the fire alarm is 
not silenced from the keypad, the fire 
alarm output continues until Fire Bell time 
expires. If the point does not restore, the 
fire alarm output continues even after bell 
time expires. 
 
 
Use this option for fire applications to 
meet the requirement that audible alarms 
cannot be silenced until the fault condition 
clears or the Fire Bell time expires. 
 
P## Audible After 2 Failures 
Default: 
No 
Selection:  Yes or No 
Yes 
A# Burg Alarm relay activates after 
two failed attempts. 
No 
P## Silent points do not cause the 
A# Burg Alarm relay to activate even 
if the report does not get to the 
central station receiver. 
When set to Yes, if the report fails to reach the 
central station after two attempts, a silent alarm rings 
the A## Burg Alarm bell. A silent alarm is generated 
when a point with P## Silent set to Yes is faulted 
while armed.