D9412GV3/D7412GV3 | Program Entry Guide | 3.0  Points 
EN | 95 
 
 
Bosch Security Systems, Inc. | 10/11 | F01U170807-02 
 
P## Buzz On Fault 
Default: 
Selection: 
0 to 3 
Selection 
Operation for Controlled Points  
(Point Types 1, 2, and 3) 
Operation for 24-hour, Fire and Aux AC 
Supervision Points (Point Types 0 and 
11) 
The point buzzes at the keypad only if it enters 
into the trouble condition indicated in the P## 
Point Response
Same as operation for controlled points 
The point generates a Buzz Until Restore at the 
keypad for any fault condition while the point 
is disarmed
. The buzz continues until the point 
restores and the user acknowledges the 
condition using a passcode or COMMAND 4. 
The point must be normal before the user can 
silence the buzz. 
The point generates a Buzz Until Restore at 
the keypad for any fault condition 
regardless of the armed state
. The buzz 
continues until the point restores and the 
user acknowledges the condition using a 
passcode or COMMAND 4. The point must 
be normal before the user can silence the 
buzz. 
The point buzzes at the keypad for any fault 
condition
 when the point is disarmed. The 
user can silence the buzz before the point 
returns to normal. 
The point buzzes at the keypad for any fault 
condition regardless of the armed state

The point does not need to be normal before 
the user can silence the buzz. 
The point buzzes at the keypad for any fault 
condition when the area is disarmed. The user 
cannot silence this buzz, but it silences 
automatically when the point is restored. If the 
fault condition results in a trouble response, the 
keypad continues to buzz even after the user 
acknowledges the condition if the fault is still 
present. 
The point buzzes at the keypad for any fault 
condition regardless of the armed state
.  
The user cannot silence this buzz, but it 
silences automatically when the point is 
restored. If the fault condition results in a 
trouble response, the keypad continues to 
buzz even after the user acknowledges the 
condition if the fault is still present. 
 
 
Points bypassed (by the user, Sked, Swinger Bypass, or RPS) do not generate a Buzz On Fault 
condition at the keypad. 
 
 
The buzz does not automatically stop when the point is restored when using Option 1 or 2. The user 
must acknowledge the buzz before the buzz stops. However, when using Option 3, the buzz stops 
automatically when the point restores to normal without user intervention. 
 
 
 
If a point with the type of 11 Aux AC Supervision is bypassed, 24 HOUR PT BYPASSED is shown 
on the keypads.