Fujitsu Primergy TX150 S6 VFY:T1506SF040IT Data Sheet

Product codes
VFY:T1506SF040IT
Page of 8
Datasheet
 Fujitsu PRiMERGY tX150 s6 sERvER
Page 5 / 8
http://ts.fujitsu.com/Primergy
seRveR ManaGeMent
standard
PDA Prefailure Detection and Anaylsis
ASR&R Automatic Server Recovery and Restart
serverview suite: 
 
SV Installation Manager
 
SV Operation Manager 
 
sv Raid Manager
 
SV Update Management 
 
SV Power Management
 
sv agents
Online update packages for BIOS, firmware drivers and ServerView Agents
ServerView Integration solutions for Microsoft SMS, MOM, SCOM, SCCM and Altiris
Deployment Solution ServerView Deployment Manager (fully functional 30-day trial version)
ServerView Deployment Manager (fully functional 30-day trial version)
option
ServerView Integration for Tivoli TEC
®
, Tivoli NetView, HP NNM and HP Operations Manager
iRMC S2 Advanced Pack
server Management notes
Regarding Operating System dependencies and product details for ServerView Suite Software Products see dedicated 
Product Data sheets.
DIMensIons / WeIGht
Dimension notes
Width 305 mm with tilt protection
Weight
up to 28 kg
Weight notes
Actual weight may vary depending on configuration
Rack integration kit
Rack integration kit as option
DIMensIons / WeIGht (Base unIt sPecIFIc)
Floor-stand (W x D x h)
205 x 605 x 
444 mm
205 x 605 x 
444 mm
205 x 605 x 
444 mm
205 x 605 x 
444 mm
-
-
-
-
Rack (W x D x h)
-
-
-
-
482 x 642 x 
221 mm
482 x 642 x 
221 mm
482 x 642 x 
221 mm
482 x 642 x 
221 mm
Mounting Depth Rack
-
-
-
-
607 mm
607 mm
607 mm
607 mm
height unit Rack
5 u
5 u
5 u
5 u
envIRonMental
noise emission
Measured according to ISO 7779 and declared according to ISO 9296
sound pressure (lpam)
26 dB(A) (idle) / 35 dB(A) (operating)
sound power (lWad; 1B = 10dB)
4.4 B (idle) / 5.3 B (operating)
noise notes / description
only with standard fans and standard PSU
operating ambient temperature
10 - 35°C
operating relative humidity
10 - 85 % (non condensing)
electRIcal values
Power supply configuration
Base unit specific:
1x standard power supply or 2x hot-plug power supply (1 + 1 redundancy) 
Rated voltage range
100 - 240 V
Rated frequency range
50 - 60 Hz
Rated current max.
6 A / 3 A (100 V / 240 V)
 
Rated current in basic configuration
1.9 A / 0.8 A (100 V / 240 V)
active power max. (per system unit)
232 W
apparent power max. (per system 
unit)
263 VA
heat emission
835.2 kJ/h (791.8 BTU)
electRIcal values (Base unIt sPecIFIc)
Power supply configuration
2
1
2
1
2
1
2
1
standard power supply output
350 W
350 W
350 W
350 W
hot-plug power supply output
400 W
-
400 W
-
400 W
-
400 W
-
hot-plug power supply redundancy
Yes
no
Yes
no
Yes
no
Yes
no
coMPlIance
Germany
Gs