Sterling SMS 850 User Manual

Page of 85
BJ5-615 
Chapter 3: Installation 
25 of 85 
 
 
   WARNING!  Use caution when operating specific equipment to prevent  electrical 
shock.  Installation, service, alterations, and/or modifications must only be done by 
qualified personnel and with high regard for safety.  Not conforming to the 
requirements could result in bodily harm, death, or costly damage. 
 
NOTE:   Alterations to the wiring diagrams require approval.  Failure to do this will 
exclude all guarantee claims. 
The wiring schematics are located in the control panel. 
 
Connection of Emergency Stop Button 
The machine may only be operated with installed Emergency Stop buttons.  An 
Emergency Stop button must be installed at the control cabinet and at the grinding 
material in-feed if no Emergency Stop buttons have been installed at the factory. 
NOTE:   The control panel with the switches and Emergency Stop button must be installed 
near the machine.  The distance should not exceed 5 m. 
The distance between the floor and the lower edge of the control panel should be 
at least 1 m. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
The connecting cables between the control panel and the machine must be protected 
against damage (cable tray, protective sleeve). 
An additional Emergency Stop button has to be installed on the machine if the control 
box cannot be installed according to these rules.