Wagner SprayTech 9155 User Manual

Page of 28
 
9
English
Preparing the Spray Hose and Spray Gun
The spray tip assembly should not be attached to the spray gun when purging the spray hose.  Failure to comply 
could result in an injection injury.
  1.  Unlock the spray gun and turn the PRIME/SPRAY knob 
to PRIME.  
  2.  PULL the trigger and aim the spray gun at the side wall 
of a waste container.
  3.  While pulling the trigger, switch the pump ON (l), and 
turn the PRIME/SPRAY knob to SPRAY.  Hold the 
trigger until all air, water, or solvent is purged from the 
spray hose and material is flowing freely. 
  4.  Release trigger and perform the Pressure Relief 
Procedure, page 7).  
  5.  Lock the spray gun trigger.   
  6.  Make sure the saddle seat and black seal are in 
place inside the tip guard nut (see Components and 
Description, page 5). 
  7.  Insert spray tip (a) into the side of the spray guard (b).  
The pointed end (c) of the spray tip should be facing 
forward as shown.
(a)
(c)
(b)
  8.  Thread the spray tip guard assembly onto the gun.  
Tighten by hand.  
SPRAY
PR
IM
E
If using oil-based materials, the spray gun must be 
grounded (see Grounding the Spray Gun, page 7).
SPRAY
PR
IM
E
+
+
l
Whenever the PRIME/SPRAY knob is still on 
SPRAY, there will be high pressure in the hose 
and spray gun until the PRIME/SPRAY knob is 
turned to PRIME.
Begin
tightening
the tip at
this angle
. . .to achieve
the desired
spray angle
when tight.