Fujitsu C120-E361-04EN User Manual

Page of 36
C120-E361-04EN
A-1
Appendix A  Troubleshooting
A
This appendix explains how to deal with possible problems during the RCI setup.
z
z
A.1
In the Case Where Setrci Command Ended 
Abnormally and Displayed “Operation Failed 
Error Status: XX”
When the RCI construction by the setrci command ended abnormally and "Operation 
failed error status: XX" is displayed, the displayed error status code, explanation, and 
remedy pattern are described to the following table.
Table A.1  The Error Status Code and Explanation
Code
Explanation
Remedy 
pattarn
00
Detected the duplicate RCI address.
01
RCI address of current unit is not configured or false.
02
Detected the duplicate RCI address of RCI host, or detected the 
undefined RCI address.
03
RCI address of current unit is not configured.
04
Over maximum entry of RCI table.
05
Detected anomaly in RCI table receiving.
06
Detected anomaly in RCI table sending.
07
Receiving status check from undefined RCI device.
08
Detected the loss of RCI master.
09
Detected anomaly of RCI table.
0a
Synchronous time out of RCI table.
0b
Synchronous retry out of RCI table.
0c
Detected anomaly of RCI table.
0d
Failed the version check of RCI table.
0e
Detected anomaly of RCI table.
0f
Detected anomaly in synchronous with RCI Neuron chip.