DELL 201S User Manual

Page of 148
7-2
Dell PowerVault 200S, 201S, 210S, and 211S Storage Systems Installation and Service Guide
" -) #  #
;2<0& * *<#
#    $ $
# !
NOTE: For the PowerVault 2xxS to power on, the PowerVault 2xxS must be attached 
to a host adapter and the host server must be powered on.
The following subsections provide general troubleshooting information for various 
components of the PowerVault 2xxS storage systems.
The amber system fault indicator 
 located on the enclosure (see "Indicators" in 
Chapter 1) lights if one of the storage system's internal self-tests fails during system 
start-up or whenever one of the following faults is detected:
Power supply fault — The amber power supply fault indicator  
located 
on 
the back panel (see "Indicators" in Chapter 1) lights if a power supply fault is 
detected.
Fan fault — The amber cooling fan fault indicator 
 located on the back panel 
(see "Indicators" in Chapter 1) lights if a cooling fan fault is detected.
Small computer system interface (SCSI) hard-disk drive fault — The amber drive 
fault indicator
 
 located at the top of each SCSI hard-disk drive carrier (see
 "Indicators" in Chapter 1) lights if a disk failure is detected.
Temperature fault — The amber system fault indicator 
 located on the 
NOTE: You can use Dell OpenManage Hardware instrumentation Package (HIP)  
to manage the system temperature. See the HP OpenView Network Node 
Manager Special Edition (NNM SE) x.x and Dell OpenManage HIP x.x 
documentation.
Table 7-1 lists the indicators that can be displayed and suggested remedies for each 
situation.