7-6
Dell PowerVault 200S, 201S, 210S, and 211S Storage Systems Installation and Service Guide
c.
Replace the SCSI backplane board.
Before replacing the SCSI backplane board, consider obtaining technical 
assistance to see if other checks should be performed.
Is the problem resolved?
Yes. End troubleshooting.
No. See Chapter 8, "Getting Help," for instructions on obtaining technical 
assistance.
 
A redundant storage system contains three cooling fans, and a nonredundant storage
system contains two cooling fans. If the amber cooling fan fault indicator  
lights 
up (see Figure 7-1) or the HP OpenView NNM SE x.x and the Dell OpenManage 
HIP x.x server management programs issue a fan-related error message, replace the 
fan as described in "Replacing a Cooling Fan," found later in this chapter.
 
1
Fan fault indicator
2
Captive screws