DELL 201S User Manual

Page of 148
7-20
Dell PowerVault 200S, 201S, 210S, and 211S Storage Systems Installation and Service Guide
& 64 !45!2*
6.
Install the replacement dual-bus split backplane module onto the backplane 
board. The dual-bus split backplane module is keyed, but make sure you do not 
bend the contact pins.
7.
Reinstall the component mounting bracket (see "Removing and Reinstalling the 
Component Mounting Bracket,
" found earlier in this chapter).
8.
Reinstall the enclosure module(s) (see "Replacing an Enclosure Module," found 
earlier in this chapter).
9.
Reinstall all of the cooling fans (see "Replacing a Cooling Fan," found earlier in this 
chapter).
10. Reinstall all of the power supplies (see "Replacing the Power Supply," found ear-
lier in this chapter).
" $! $
To remove the SCSI backplane board, perform the following steps:
1.
Remove all of the hard-disk drives from the storage system (see "Removing and 
Installing SCSI Hard-Disk Drives in the Drive Bays"
 in Chapter 6).
2.
Remove all power supplies from the back of the storage system (see "Replacing 
the Power Supply,
" found earlier in this chapter).
1
Dual-bus split backplane module