Q-Logic 59047-10 D User Manual
4–Fibre Alliance MIB Objects
connUnitStatus (1.3.6.1.3.94.1.6.1.6)
4-8
59047-10 D
connUnitStatus (1.3.6.1.3.94.1.6.1.6)
Overall status of the connectivity unit. The goal of this object is to be the single
poll point to check the status of the connunit. If there is any other component that
has warning, then this should be set to warning. any of these values may occur
with any of the ConnUnitState values.
poll point to check the status of the connunit. If there is any other component that
has warning, then this should be set to warning. any of these values may occur
with any of the ConnUnitState values.
Syntax
INTEGER
Access
read-only
Status
mandatory
Return Value
Refer to
for connectivity unit return values. Return value will be OK
(3), unless one or more of the following occurs.
other unknown
(1)
Table 4-3. QLogic 5000 Series Connectivity Unit Return Values
Status
Return Value
If one power supply is reporting Bad
and/or not installed
and/or not installed
warning (4)
If both power supplies are reporting Bad
and/or not installed
and/or not installed
failed (5)
If one or more cooling fan failed
warning (4)
If all cooling fans failed
failed (5)
If temperature status = "Warm"
warning (4)
If temperature status = "Overheating"
failed (5)
If any port down
warning (4)
If POST failed
failed (5)
If switch Offline or in Diagnostics mode
warning (4)
Table 4-2. Switch Operational States (Continued)
Switch State
Return State