Q-Logic 59047-10 D User Manual

Page of 264
4–Fibre Alliance MIB Objects
connUnitEventFilter (1.3.6.1.3.94.1.6.1.25)
59047-10  D
4-17
connUnitEventFilter (1.3.6.1.3.94.1.6.1.25)
This value defines the event severity that will be logged by this connectivity unit. 
All events of severity less than or equal to connUnitEventFilter are logged in 
connUnitEventTable.
Syntax
FcEventSeverity
Access
read-write 
Status
mandatory
Return Value
The switch log level setting. Refer to the following tables for 
connUnitEventFilter values.
Table 4-7. connUnitEventFilter Read Return Values
Severity Levels
Return Value
Critical
Critical (4)
Warn
Warning (6)
Info
Info (8)
None
Unknown (1)
Table 4-8. connUnitEventFilter Control Write Values
Control Value
Result
Emergency (2)
Critical
Alert (3)
Critical
Critical (4)
Critical
Error (5)
Warn
Warning (6)
Warn
Notify (7)
Info
Info (8)
Info
Debug (9)
Info
Mark (10)
Info
Unknown (1)
None