XEROX DOCUPRINT 180 LPS OVERVIEW
XEROX DOCUPRINT 180 LASER PRINTING SYSTEM PRODUCT GUIDE
1-9
Electrical requirements
Table 1-4 shows the electrical requirements for the Xerox DocuPrint 
180 LPS.
Note:
For more information on Xerox DocuPrint 180 LPS electrical 
requirements, including power cord and outlet specifications, refer to 
the 
Xerox DocuPrint 180 LPS Installation Planning Guide
Table 1-4.
DocuPrint 180 electrical requirements
Electrical requirements
Printer
Dual cord system (60Hz):
Cord 1:     120/208 VAC(182V to 220V) (2 phase),  50 amp dedicated service
Cord 2:     120/208 VAC(182V to 220V) (2 phase),  30 amp dedicated service
Single cord system (50Hz):
WYE:     80/400/415 VAC (3 phase, 5 wire), 20 amp dedicated service
Delta:     220/230/240 VAC (3 phase, 4 wire), 30 amp dedicated service
KVA rating:     7.3 (operating)
System Controller
U.S. and Canada, 60 Hz:
     208/240 VAC (1 phase) or 208/220 VAC (Line 1 to Line 2);
     15 amp service
     NEMA 6-15R or ANSI C73, 20R
     KVA 1.1 (operating)
International, 50 Hz:
     200/230 VAC (1 phase)
     15 amp service;
     Power connector per local codes
Optional Peripheral Cabinet U.S. and Canada, 60Hz:
     208/240 VAC (1 phase) or
     208/220 VAC (Line 1 to line 2);
     15 amp service;
     NEMA6-15R or ANSI C73, 20R
     KVA .9 in both standby and operation
International, 50 Hz:
     200/230 VAC (1 phase);
     15 amp service;
     Power connector per local codes
Optional bypass transport
The power requirements for the bypass transport module are all satisfied by the 
DocuPrint 180 LPS printer module.
Agency certification
UL, CSA, IEC, VDE