Chapter 23 Replacing or upgrading a power supply
293
BCM200/400 4.0 Installation and Maintenance Guide
Figure 154   Install a cable grommet
20 Install the main unit top cover. See 
.
Removing a BCM400 redundant power supply cage
Use this procedure to remove an existing redundant power supply cage from the BCM400 main 
unit.
To remove a BCM400 redundant power supply cage
1
Set up the BCM400 for maintenance (see 
).
2
Disconnect all cables from the front of the base function tray.
3
Disconnect the main unit and the expansion unit (if applicable), from the AC power 
connection.
4
Remove the top cover from the BCM400 main unit (see 
).
5
Attach one end of the grounding strap to your wrist and the other end to a grounded metal 
surface.
6
Remove the power supply modules (see 
7
Partially remove the power supply module from the power supply cage. Do not completely 
remove the power supply module.
Warning: Protect the hardware components against damage from electrostatic discharge. 
Always wear a grounded wrist strap before you handle components. Always place the 
components in a static-free container.
Cable grommet
Insert the P2, P3 
and auxiliary 
cables into the 
cable slot
Cable slot