Nortel Networks 400 4.0 User Manual
Appendix B BRIM wiring chart
337
BCM200/400 4.0 Installation and Maintenance Guide
Appendix B
BRIM wiring chart
The digital BRI ISDN lines are connected to the BRIM through the RJ-45 jacks on the front of the
media bay module (MBM) (see
media bay module (MBM) (see
). You can connect up to four BRI ISDN lines to the
BRIM.
apply to S-Loop and T-Loop connections. S-Loop connections are used
to connect S-Loop devices, such as video phones, terminal adapters, and group 3 fax machines.
The T-Loop connections are used to connect to the CO/PSTN.
The T-Loop connections are used to connect to the CO/PSTN.
Figure 190 BRIM RJ-45 ports
lists the wiring details for the RJ-45 ports.
Warning: For a U-Loop connection, the BRIM must be connected only to an NT1
provided by the service provider. The NT1 must provide a Telecommunication Network
Voltage (TNV) to Safety Extra Low Voltage (SELV) barrier.
provided by the service provider. The NT1 must provide a Telecommunication Network
Voltage (TNV) to Safety Extra Low Voltage (SELV) barrier.
Table 86 BRIM RJ-45 port wiring
Pin
Signal
Signal on system side
1
No connection
No connection
2
No connection
No connection
3
+ Receive (+Rx)
+Tx
4
+ Transmit (+Tx)
+Rx
5
- Transmit (-Tx)
-Rx
6
- Receive (-Rx)
-Tx
7
No connection
No connection
8
No connection
No connection
1 2 3 4 5 6 7 8
RJ-45 pin-out
RJ-45 jacks
BRIM