Chapter 2 Introducing the BCM hardware
N0060612
N0060612
Figure 21   BCM expansion unit connected to BCM400 main unit
MBM bays and backplane
The number and configuration of the MBMs depend on the number of bays available in the main 
unit and DS30 system resources. The BCM200 main unit provides two MBM bays. The BCM400 
main unit provides four MBM bays. 
All MBM bays must contain either an MBM or an MBM filler blanking plate. Fill unpopulated 
MBM bay openings in the main unit with the MBM filler blanking plates (see 
).
Figure 22   MBM filler blanking plate
The MBMs slide into the MBM bays and lock into place. Pull on the MBM ejector to release the 
MBM or filler blanking plate. The MBM or filler blanking plate partially ejects from the bay. Slide 
the MBM out of the bay to remove it from the main unit. 
BCM expansion unit
NEEd
DS256 port
BCM400 main unit
DS256 port
Filler blanking plate 
face
Locking clip