ZyXEL Communications VSG-1200 User Manual

Page of 280
VSG-1200 User’s Guide
84
Chapter 7 Billing Profiles and PMS Configuration
7.3  Types of Subscriber Accounts
After you have set up the subscriber authentication methods and billing profile(s), you need to 
create subscriber accounts. There are two types of subscriber accounts: static and dynamic.
• For static accounts, refer to 
.
• For dynamic accounts, refer to 
Table 21   System Setting: Billing: PMS Configuration 
LABEL
DESCRIPTION
Charge Mode (only 
for Port-Location 
Mapping enabled)
When you set up Port-Location Mapping, your VSG offers two billing modes: 
Based on Room and Based on Subscriber.
Select Based on Room when location is important. If a subscriber disconnects 
from one location and reconnects in another location, the VSG prompts for the 
user name and password again.
Select Based on Subscriber to allow a subscriber to freely move between 
different locations without prompting for user name and password.
Note: You must activate the port-location mapping feature. Refer 
to 
Regenerate 
password of static 
account with PMS 
checkout.
This feature is applicable when you select Scenario B with Built-in 
Authentication in the Authentication screen (see 
). 
Select Enable to automatically generate a new password for the static account 
when a subscriber checks out.
Select Disable to keep the password for the static account unchanged after a 
subscriber checks out.
PMS Type
Select a PMS system and specify the fields below (if available). Currently the 
VSG supports Micros FidelioSpectrum MK IIMarriott and Proprietary
Revenue Code Enter a revenue code (between 01 and 99).
Description Enter the description for the revenue. Refer to the user’s guide that comes with 
your PMS device.
Speed of PMS 
Interface 
Set the fields below to configure the PMS port settings on the VSG. 
Note: Make sure the port settings are the same on the VSG and 
the connected PMS device. 
Bits per second Select the speed of the PMS port connection. The default is 9600.  
Data bits Specify the data bits. 
Parity Specify the parity. 
Stop bits Specify the data stop bits. 
Apply