2-26
MPC8260 PowerQUICC II UserÕs Manual
MOTOROLA
Part I. Overview
2.5.3  Exception Priorities
The exception priorities for the processor core are unchanged from those described in the
MPC603e UserÕs Manual except for the alignment exception, whose causes are prioritized
as follows:
1. Floating-point operand not word-aligned
2. lmwstmwlwarx, or stwcx. operand not word-aligned
3. eciwx or ecowx operand misaligned 
4. A multiple or string access is attempted with MSR[LE] set
2.6  Memory Management
The following subsections describe the memory management features of the PowerPC
architecture and the MPC8260 implementation.
Trace
00D00
A trace exception is taken when MSR[SE] = 1 or when the currently completing 
instruction is a branch and MSR[BE] = 1.
Floating-point 
assist
00E00
Not implemented.
Reserved
00E10Ð00FFF Ñ
Instruction 
translation 
miss
01000
An instruction translation miss exception is caused when the effective address for 
an instruction fetch cannot be translated by the ITLB.
Data load 
translation 
miss
01100
A data load translation miss exception is caused when the effective address for a 
data load operation cannot be translated by the DTLB.
Data store 
translation 
miss
01200
A data store translation miss exception is caused when the effective address for a 
data store operation cannot be translated by the DTLB, or when a DTLB hit occurs, 
and the changed bit in the PTE must be set due to a data store operation.
Instruction 
address 
breakpoint
01300
An instruction address breakpoint exception occurs when the address (bits 0Ð29) in 
the IABR matches the next instruction to complete in the completion unit, and the 
IABR enable bit (bit 30) is set. 
System 
management 
interrupt
01400
A system management interrupt is caused when MSR[EE] = 1 and the SMI input 
signal is asserted.
Reserved
01500Ð02FFF
Ñ
Table 2-5. Exceptions and Conditions (Continued)
Exception 
Type
Vector Offset
(hex)
Causing Conditions