Motorola MPC8260 User Manual

Page of 1006
 
4-31
MPC8260 PowerQUICC II UserÕs Manual
MOTOROLA
Part II. ConÞguration and Reset
4.3.2.6  SIU Module ConÞguration Register (SIUMCR)
The SIU module conÞguration register (SIUMCR), shown in Figure 4-28, contains bits that
conÞgure various features in the SIU module.
Bit
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Field
Priority Field 8
Priority Field 9
Priority Field 10
Priority Field 11
Reset
1000
1001
1010
1011
R/W
R/W
Addr
Bit
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
Field
Priority Field 12
Priority Field 13
Priority Field 14
Priority Field 15
Reset
1100
1101
1110
1111
R/W
R/W
Addr
0x1003E
Figure 4-27. LCL_ALRL
Bits
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Field
BBD
ESE
PBSE
CDIS
DPPC
L2CPC
LBPC
APPC
CS10PC
BCTLC
Reset
0000_0000_0000_0000
R/W
Depends on reset conÞguration sequence. See Section 5.4.1, ÒHard Reset ConÞguration Word.Ó
Addr
Bits
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
Field
MMR
LPBSE
Ñ
Reset
0000_0000_0000_0000
R/W
Depends on reset conÞguration sequence. See Section 5.4.1, ÒHard Reset ConÞguration Word.Ó
Addr
0x10002
Figure 4-28. SIU Model Configuration Register (SIUMCR)