26.4.6  SMC Transparent Commands
Table 26-11 describes receive commands issued to the CPCR. 
26.4.7  Handling Errors in the SMC Transparent Controller
The SMC uses BDs and the SMCE to report message send and receive errors. 
Table 26-10. SMC Transparent Transmit Commands 
Command Description
STOP
 
TRANSMIT
After hardware or software is reset and the channel is enabled in the SMCM, the channel is in transmit 
enable mode and polls the Þrst BD. This command disables transmission of frames on the transmit 
channel. If the transparent controller receives this command while sending a frame, it stops after the 
contents of the FIFO are sent (up to 2 characters). The TBPTR is not advanced to the next BD, no new 
BD is accessed, and no new buffers are sent for this channel. The transmitter sends idles until a 
RESTART
 
TRANSMIT
 command is issued.
RESTART
 
TRANSMIT
Starts or resumes transmission from the current TBPTR in the channel TxBD table. When the channel 
receives this command, it polls the R bit in this BD. The SMC expects this command after a 
STOP
 
TRANSMIT
 is issued. The channel in its mode register is disabled or after a transmitter error occurs.
INIT
 
TX
 
PARAMETERS
Initializes transmit parameters in this serial channel to reset state. Use only if the transmitter is 
disabled. The 
INIT
 
TX
 
AND
 
RX
 
PARAMETERS
 command resets transmit and receive parameters.
Table 26-11. SMC Transparent Receive Commands 
Command Description
ENTER
 
HUNT
 
MODE
Forces the SMC to close the current receive BD if it is in use and to use the next BD for subsequent 
data. If the SMC is not receiving data, the buffer is not closed. Additionally, this command causes the 
receiver to wait for a resynchronization before reception resumes.
CLOSE
 
RXBD
Forces the SMC to close the current receive BD if it in use and to use the next BD in the list for 
subsequent received data. If the SMC is not in the process of receiving data, no action is taken.
i
NIT
 
RX
 
PARAMETERS
Initializes receive parameters in this serial channel to reset state. Use only if the receiver is disabled. 
The 
INIT
 
TX
 
AND
 
RX
 
PARAMETERS
 command resets receive and transmit parameters.
Table 26-12. SMC Transparent Error Conditions
Error
Descriptions
Underrun The channel stops sending the buffer, closes it, sets UN in the BD, and generates a TXE interrupt if it is 
enabled. The channel resumes sending after a 
RESTART
 
TRANSMIT
 command. Underrun cannot occur 
between frames.
Overrun
The SMC maintains an internal FIFO for receiving data. If the buffer is in external memory, the CP begins 
programming the SDMA channel when the Þrst character is received into the FIFO. If a FIFO overrun 
occurs, the SMC writes the received data character over the previously received character. The previous 
character and its status bits are lost. Then the channel closes the buffer, sets OV in the BD, and generates 
the RXB interrupt if it is enabled. Reception continues as normal.