Motorola MPC8260 User Manual

Page of 1006
MOTOROLA
Chapter  34.  I2C Controller  
34-11
Part IV.  Communications Processor Module
Figure 34-11 shows the RFCR/TFCR bit Þelds.
34.6  I
2
C Commands
The I
2
C transmit and receive commands, shown in Table 34-8, are issued to the CP
command register (CPCR).
Bit
0
1
2
3
4
5
6
7
Field
GBL
BO
TC2
DTB
Ñ
Reset
0000_0000
R/W
R/W
Addr
I2C_BASE + 04 (RFCR)/I2C_BASE + 05 (TFCR)
Figure 34-11. I
2
C Function Code Registers (RFCR/TFCR)
Table 34-7. RFCR/TFCR Field Descriptions
Bits
Name
Description 
0Ð1
Ñ
Reserved, should be cleared.
2
GBL
Global access bit
0 Disable memory snooping
0 Enable memory snooping
3Ð4
BO
Byte ordering. Set BO to select the required byte ordering for the buffer. If BO is changed on-the-ßy, it 
takes effect at the beginning of the next frame or BD. 
00  True little-endian. Note this mode can only be used with 32-bit port size memory.
01   PowerPC little-endian. 
1x  Big-endian.
5
TC2
Transfer code 2. Contains the transfer code value of TC[2], used during this SDMA channel memory 
access. TC[0Ð1] is driven with a 0b11 to identify this SDMA channel access as a DMA-type access.
6
DTB
Data bus indicator.
0 Use 60x bus for SDMA operation.
1 Use local bus for SDMA operation. 
7
Ñ
Reserved, should be cleared.
Table 34-8. I
2
C Transmit/Receive Commands 
Command
Description
INIT
 
TX
 
PARAMETERS
Initializes all transmit parameters in the parameter RAM to their reset state. Should be issued only 
when the transmitter is disabled. The 
INIT
 
TX
 
AND
 
RX
 
PARAMETERS
 command can also be used to reset 
both the Tx and Rx parameters.
CLOSE
 
RXBD
Forces the I
2
C controller to close the current Rx BD and use the next BD for subsequently received 
data. If the controller is not receiving data, no action is taken. Use this command to extract data from a 
partially full buffer.
INIT
 
RX
 
PARAMETERS
Initializes all receive parameters in the parameter RAM to their reset state. Should be issued only when 
the receiver is disabled. The 
INIT
 
TX
 
AND
 
RX
 
PARAMETERS
 command can also be used to reset both the 
Tx and Rx parameters.