Emerson MMI-20019043 User Manual

Page of 374
Options for Discrete Output Source
 (continued)
Table 6-9:   
Option
Label
Condition
Discrete out-
put voltage
Display
ProLink II
ProLink III
Field Commu-
nicator
Enhanced Event
4
Enhanced Event
5
OFF
0  V
Event 1–2
(2)
EVNT1
EVNT2
E1OR2
Event  1
Event  2
Event  1 or
Event  2
Event 1
Event 2
Event 1 or Event
2 Status
Event  1
Event  2
Event  1 or
Event  2
ON
Site-specific
OFF
0  V
Flow Switch
FL SW
Flow Switch In-
dication
Flow Switch Indi-
cator
Flow Switch
ON
Site-specific
OFF
0  V
Flow Direction
FLDIR
Forward/Re-
verse Indica-
tion
Forward Reverse
Indicator
Forward/Re-
verse
Forward flow
0  V
Reverse flow
Site-specific
Calibration in Pro-
gress
ZERO
Calibration in
Progress
Calibration in Pro-
gress
Calibration in
Progress
ON
Site-specific
OFF
0  V
Fault
FAULT
Fault Condition
Indication
Fault Indication
Fault
ON
Site-specific
OFF
0  V
Important
This table assumes that Discrete Output Polarity is set to Active High. If Discrete Output Polarity is set to Active
Low
, reverse the voltage values.
Important
If you assign flow switch to the discrete output, you must also configure Flow Switch Variable, Flow
Switch Setpoint
, and Hysteresis.
(2) Events configured using the basic event model.
Integrate the meter with the control system
116
Micro Motion
®
 Model 2700 Transmitters with Analog Outputs