Lopi Yankee Bay Pellet Insert User Manual

Page of 40
6
Specifications
Travis Industries
4 0 5 0 5 0 9
1 0 0 - 0 1 1 4 5
Heating Specifications:
Approximate Maximum Heating Capacity (in square feet)* ........................................800 to 2,250
Burn Rate (Pounds per Hour)**............................................................................1.7 to 5.5
Maximum Burn Time on Low Burn** ......................................................................28 to 52 Hours
Hopper Capacity (based upon hopper extension position).........................................48 to 89 Pounds
*
Heating capacity will vary depending on the home's floor plan, degree of insulation, and the outside temperature.  It is also
affected by the fuel size, quality, and moisture level.
**
Small pellets will increase or decrease the stated burn rates and burn times.  Differences of plus or minus 20% depending
on fuel quality may occur.
Dimensions:
12"
13-1/4” (allow 14” depth in the Fireplace)
32”
Center of 4” diameter Flue is 16-7/8” above the 
baseplate and 7-1/2” left of center
25-3/4” to 20”
See “Hopper Extension Set-up”  
for details.
25-1/2” (allow 36” width for 
control board installation)
26-1/2”
45”
Door Opening
Fireplace Opening
28
Electrical Specifications:
Electrical Rating.........................................................................................115 Volts, 3.6 Amps, 60 Hz
Watts During Start-Up Sequence ...................................................................400 (approximately)
Watts During Operation ...............................................................................180 (approximately)
Fuel:
The unit is designed for wood pellets that comply with the standards set by the Association of Pellet Fuel
Industry (density of at least 40 lbs. per cubic foot, 1/4" to 5/16" diameter, length no greater than 1–1/2", 8200
BTU's/lb., moisture under 8% by weight, ash under 1% by weight, and salt under 300 parts per million).  If the fuel
does not comply to this standard, the unit may not operate as designed.
N O T E
   : This heater may use alternative fuel if equipped with the multi-fuel fire pot and properly maintained.  See the
publication “Multi-Fuel Pellet Fire Pot” for requirements (available from your Travis Industries, Inc. dealer).
EPA Compliance:
This heater is EPA exempt from Phase II requirements, but has been tested for emissions using EPA
test methods by OMNI Test Labs.