Runco SP-50 User Manual

Page of 84
Runco CinemaWall SP-42/-50/-60 Owner’s Operating Manual
43 
PRE
L
IMINAR
Y
Auto Function: The CinemaWall can automatically switch to Input 1 or Input 4 (Model 
SP-50/SP-60 only) when an image signal is detected at that input. To enable this feature, 
select Auto Function from the Option menu and set it to INPUT 1 (or INPUT 4, on a 
Model SP-50/SP-60). 
After Auto Function triggers an input switch, when the Input 1 or Input 4 signal is no longer 
present, the input source reverts to the previously-selected input. 
Option (Installer Adjust 
Mode)
Program Timer (SP-42) / Screen Maint. (SP-50/SP-60): When in Installer Adjust 
mode, select Program Timer (SP-42) / Screen Maint. (SP-50/SP-60) from the Option 
menu to program the screen maintenance features of the CinemaWall to operate at 
regular intervals. This is useful for preventing image burn-in. 
You can program the CinemaWall to switch inputs and/or replace the normal source 
signal with a white field, an inverse image or an “orbiting” image. You can specify a time of 
day and day of the week when you want this to take place. 
To set up a screen maintenance program:
1. Press SET to select the DATE field for the first program. Press 
 or 
 to select one of 
the following:
• SUN, MON, TUE, WED, THU, FRI or SAT for a program that runs once only on the 
next occurrence of that day. 
• * for a program that runs daily.
• *SUN, *MON, *TUE, *WED, *THU, *FRI or *SAT for a program that runs weekly on 
that day. 
2. Press SET, then 
 followed by SET again to set the program start time.
3. Press 
 or 
 to set the hour component of the start time. 
4. Press 
then 
 or 
 to set the minute component of the start time. 
5. Press SET, then 
 followed by SET again to set the program end time (repeat steps 3 
and 4).
6. Press SET, then 
 followed by SET again to specify an input associated with this 
program. Choose “–” to specify the input that was active when the CinemaWall was 
last powered off. 
7. Press SET, then 
 followed by SET again to select the PATTERN field for this 
program. Press 
 or 
 to select one of the following:
• Choose “–” to specify the function that was active when the CinemaWall was last 
powered off. 
• Choose WHITE to display a white field. 
• Choose INVERSE to display an inverse image.
• Choose ORBITER to display an “orbiting” image. 
On the Model SP-42, Auto Function is supported on Input 1 only. 
The input signal must be RGB with composite or separate sync; 
Auto Function will not work with sync-on-green RGB or component 
signals. 
When Auto Function is active, selecting an input manually causes 
Auto Function to be temporarily disabled. If you cycle power to the 
CinemaWall, Auto Function becomes active again. 
Note
INPUT 3
INSTALLER ADJ.
SCREEN
SET-UP
OPTION
PICTURE
PROGRAM TIMER
 
TEST PATTERN
:  OFF
SIDEBAR ADJ.
 
 
 
BAUD RATE
:  9600BPS
ID NUMBER
:  ALL
ENTER
SET
EXIT
MENU
PROGRAM TIMER
DATE ON 
OFF 
INPUT  PATTERN
10:00 
– –:– – 
– 
20:00 
– –:– – 
– 
WHITE
* – 
–:– 
– 
21:00  –  –
– 
– –:– – 
– –:– – 
– 
– 
– –:– – 
– –:– – 
– 
– 
– –:– – 
– –:– – 
– 
– 
– –:– – 
– –:– – 
– 
   RETURN
ENTER
SET
EXIT
MENU