Runco SP-50 User Manual

Page of 84
Runco CinemaWall SP-42/-50/-60 Owner’s Operating Manual
53 
PRE
L
IMINAR
Y
6.1 
RS-232 Connection 
and Port Configuration
To interface the CinemaWall with a home theater automation/control system or a PC 
running terminal emulation software, connect it to your control system or PC as shown in 
Figure 3-13. 
Configure the RS-232 controller or PC serial port as follows: no parity, 8 data bits, 1 stop 
bit and no flow control. Set its baud rate to 115200, to match that of the CinemaWall 
RS-232 port.
6.2 
Serial Command 
Syntax
Serial commands to the CinemaWall take the following form:
• You can send commands in either hexadecimal or ASCII format. 
• ASCII commands are not case-sensitive. 
• Commands begin with the “Start of Text” (STX) character (02h or <Ctrl> B in ASCII), 
followed by the display ID (2 bytes), the command data and command argument 
(3 or 6 bytes; refer to Table 6-1) and the “End of Text” (ETX) character (03h or 
<Ctrl>
 C
 in ASCII).
• You do not need to send a carriage return after the command. 
• The default CinemaWall display ID is 01 (30h 31h). With most commands, you can also 
use the “wildcard” display ID of “**” (2Ah 2Ah) in place of any value for the ID. However, 
when requesting status via serial commands, you must use a specific display ID; “**” 
does not work in these cases. 
Example
For example, if the CinemaWall ID number is set to its default value (01 = 30h 31h), send 
the following sequence to set the contrast to its highest possible level (255):  
6. Serial Communications
STX
ID (2 bytes)
Command (3 bytes) Argument (3 bytes)
ETX
Hex
02
30 31
or
2A 2A
43 4E 54
32 35 35
03
ASCII
<Ctrl>
 B
0 1
or
* *
C   N   T
2   5   5
<Ctrl>
 C