Error messages
(continued)
Error messages
Priority
Display
Description
VTR operation and remedial action
Higher
Lower
E-01
LOW RF
This is indicated when the embed level of the video 
head during playback, recording, and editing is about 
1/3 the normal level or less and is detected for 1 
second or more, or when the CTL level of the A/C 
head is about 1/6 of the normal level or less and is 
detected for 1 second or more.
z The CTL level is not detected when DV/DVCAM is 
played back.
z During recording and editing, only the embed level of 
simultaneous playback of video is detected.
VTR: Operation continues.
z Execute the cleaning operation for the video and A/C 
heads.
E-02
HIGH ERROR RATE
This is displayed when the error rate increases and 
correction or interpolation is performed for either the 
video or audio signals.
VTR: Operation continues.
z Clean the video heads.
Display
Description
VTR operation and remedial action
E-20
DEW
When condensation has been detected, the 
AUTO OFF lamp lights, the message display 
blinks, and the VTR transfers to the EJECT mode.  
After the tape has been ejected, the drum 
continues to rotate in order to dry out the 
condensation.
When the condensation has cleared, the AUTO 
OFF lamp goes off, the message display is cleared, 
and the VTR is ready for operation again.
z When condensation is detected in the EJECT 
mode, the drum starts rotating as soon as it is 
detected.
z When condensation is detected while a cassette 
is inserted, the drum stops rotating and starts 
rotating again after the tape has been ejected.
VTR: EJECT
z Wait with the power on.
E-29
FRONT LOAD 
MOTOR
If the cassette fails to move up even after 6 
seconds have elapsed since the VTR transferred 
to the EJECT mode, the AUTO OFF lamp lights, 
and the message display blinks.
<Note>
If the cassette fails to move down even after 6 
seconds have elapsed since the cassette was 
inserted, the VTR transfers to the EJECT mode.
VTR: Stops.
z Set the POWER switch to OFF and then back to 
ON again.
E-31
LOADING 
MOTOR
If the unloading operation fails to be completed 
within 6 seconds, the AUTO OFF lamp lights, and 
the message display blinks.
<Note>  
If the loading operation fails to be completed 
within 6 seconds, the VTR transfers to the EJECT 
mode (unloading mode).
VTR: Stops.
z Set the POWER switch to OFF and then back to 
ON again.
E-35
SERVO 
CONTROL 
ERROR
When there is no response from the servo 
microcomputer for 1 or more seconds, the AUTO 
OFF lamp lights, and the message display blinks.
VTR: Stops.
z Set the POWER switch to OFF and then back to 
ON again.
E-37
SERVO COMM 
ERROR
When the servo microcomputer does not follow 
the instructions of the system control 
microcomputer even after 10 seconds have 
elapsed, the AUTO OFF lamp lights, and the 
message display blinks.
VTR: Stops.
z Set the POWER switch to OFF and then back to 