Binary & DMX DIP-switch Addressing 
Each DIP-switch has an associated value. Adding the value of each switch in the ON position will 
provide the final address. Determining which switches to toggle ON given a specific desired address 
or value can be accomplished in the following manner. By subtracting the largest switch value 
possible from the selected start address which does not cause a negative number. 
Alternatively, using the “Binary Addressing Quick Reference Chart” in the Appendix section of this 
manual, you can go directly to DIP-switch settings associated with all 512 values available.  
 
 
E
XAMPLE 
A
DDRESS
 
 
Address 10 
Pin # 4 
= 8 
Pin # 2 
= 2 
Total  
= 10 
 
Address 24 
Pin # 5 
= 16 
Pin # 4 
= 8 
Total = 
24 
 
Resolving address 
using simple math.
 
Address 233
 
233 – (128) = 105, Turn ON Dip # 8 
105 – (64) = 41, Turn ON Dip # 7 
41 – (32) = 9, Turn ON Dip # 6 
9 – (8) = 1, Turn ON Dip # 4 
1 – (1) = 0, Turn ON Dip # 1 
 
You will most likely use the first available 