Renesas R5S72641 User Manual

Page of 2152
 
Section 24   A/D Converter 
R01UH0134EJ0400  Rev. 4.00  
 
Page 1265 of 2108 
Sep 24, 2014 
 
 
 
SH7262 Group, SH7264 Group 
Bit Bit 
Name 
Initial 
Value R/W 
Description 
13 ADST  0  R/W 
A/D 
Start 
Starts or stops A/D conversion. This bit remains set to 1 
during A/D conversion. 
0: A/D conversion is stopped 
1: Single mode: A/D conversion starts. This bit is 
automatically cleared to 0 when A/D conversion ends 
on the selected channel. 
Multi mode: A/D conversion starts. This bit is 
automatically cleared to 0 when A/D conversion is 
completed cycling through the selected channels. 
Scan mode: A/D conversion starts. A/D conversion is 
continuously performed until this bit is cleared to 0 by 
software, by a power-on reset as well as by a 
transition to deep standby mode, software standby 
mode or module standby mode. 
12 to 9 
TRGS[3:0] 
0000 
R/W 
Timer Trigger Select 
These bits enable or disable starting of A/D conversion 
by a trigger signal. 
0000: Start of A/D conversion by external trigger input is 
disabled 
0001: A/D conversion is started by conversion trigger 
TRGAN from the multi-function timer pulse unit 2
0010: A/D conversion is started by conversion trigger 
TRG0N from the multi-function timer pulse unit 2
0011: A/D conversion is started by conversion trigger 
TRG4AN from the multi-function timer pulse unit 
0100: A/D conversion is started by conversion trigger 
TRG4BN from the multi-function timer pulse unit 
1001: A/D conversion is started by 
ADTRG 
Other than above: Setting prohibited