Renesas R5S72641 User Manual

Page of 2152
 
Section 11   Multi-Function Timer Pulse Unit 2 
 
R01UH0134EJ0400  Rev. 4.00  
 
Page 511 of 2108 
Sep 24, 2014 
 
 
 
SH7262 Group, SH7264 Group 
(3)  Input Capture Function 
The TCNT value can be transferred to TGR on detection of the TIOC pin input edge. 
Rising edge, falling edge, or both edges can be selected as the detected edge. For channels 0 and 1, 
it is also possible to specify another channel's counter input clock or compare match signal as the 
input capture source. 
Note:  When another channel's counter input clock is used as the input capture input for channels 
0 and 1, P
/1 should not be selected as the counter input clock used for input capture 
input. Input capture will not be generated if P
/1 is selected. 
(a)  Example of Input Capture Operation Setting Procedure 
Figure 11.10 shows an example of the input capture operation setting procedure. 
Input selection
Select input capture input
Start count
<Input capture operation>
[1]
[2]
[1] Designate TGR as an input capture 
register by means of TIOR, and select 
rising edge, falling edge, or both edges 
as the input capture source and input 
signal edge.
[2]  Set the CST bit in TSTR to 1 to start 
the count operation.
 
Figure 11.10   Example of Input Capture Operation Setting Procedure