Section 11   Multi-Function Timer Pulse Unit 2 
 
R01UH0134EJ0400  Rev. 4.00  
 
Page 581 of 2108 
Sep 24, 2014 
 
 
 
SH7262 Group, SH7264 Group 
A/D converter start request (TRG4AN)
Note: *    When the interrupt skipping count is set to two.
TGIA_3 interrupt
 skipping counter
TCIV_4 interrupt
 skipping counter
TGIA_3 A/D request-enabled
 period
TCIV_4 A/D request-enabled
 period
When linked with TGIA_3 and TCIV_4 
interrupt skipping
When linked with TGIA_3 
interrupt skipping
When linked with TCIV_4 
interrupt skipping
TADCORA_4
TCNT_4
00
01
00
01
02
00
01
00
01
02
UT4AE = 1
DT4AE = 0
 
Figure 11.76   Example of A/D Converter Start Request Signal (TRG4AN) Operation  
Linked with Interrupt Skipping