The following CLI commands are necessary for an un-configured Cisco Nexus 5548UP or Cisco Nexus 
5596. The full CLI will show additional lines that are either default or can’t be changed and are not 
added for this example. The CLI will also show the lines in a different order after they have been 
entered. 
 will have a copy of the full configuration. 
Command-Line Interface Method 
 
Sample CLI for Cisco Nexus 5548 (can be copied and pasted) 
Figure 11.
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Note that the provided Cisco commands should be referenced in the Nexus 5000 Series NX-OS 
SAN Switching Configuration Guide
The CLI entries above only cover the areas that must be added 
to enable FCoE capabilities on the particular ports being used of a Cisco Nexus 5020 and Nexus 
5548. This topic will be covered after the Step by Step explanation of the CLI example. 
 
feature fcoe 
feature npiv 
feature telnet 
feature lacp 
 
system default switchport trunk mode auto 
 
system qos 
  service-policy type qos input fcoe-default-in-policy 
  service-policy type queuing input fcoe-default-in-policy 
  service-policy type queuing output fcoe-default-out-policy 
  service-policy type network-qos fcoe-default-nq-policy 
 
 
vlan 20 
vlan 1000 
  fcoe vsan 2  
   
 
vsan database 
  vsan 2 
  vsan 2 interface vfc1 
  vsan 2 interface fc2/1 
 
interface vfc1 
  bind interface Ethernet1/1 
  no shutdown 
 
interface fc2/1 
  switchport trunk mode auto 
  no shutdown 
 
interface Ethernet1/1 
  switchport mode trunk 
  switchport trunk native vlan 20 
  switchport trunk allowed vlan 1000 
   
 
zone name blade1  vsan 2 
    member interface fc2/1  
    member pwwn xx:xx:xx:xx:xx:xx:xx:xx 
 
zoneset name set1 vsan 2 
    member blade1 
 
zoneset activate name set1 vsan 2