Bosch D9412GV2 User Manual
D9412GV2/D7412GV2 | Operation and Installation Guide | 3.0 Overview
.
Bosch Security Systems, Inc. | 5/05 | F01U003641B
9
3.0 Overview
3.1
Configuration and Parts
Figure 1:
System Configuration
Use keypads or keyswitches to arm the control
panel by area. Each control panel can have up to eight
areas. Each area can have its own account number or
areas can be grouped together with a common account
number. Points of protection are assigned to areas.
panel by area. Each control panel can have up to eight
areas. Each area can have its own account number or
areas can be grouped together with a common account
number. Points of protection are assigned to areas.
Control
Panel
On-Board Points
1 to 8
D9131A Module connects
to a parallel printer to print
the event log.
to a parallel printer to print
the event log.
D928 Module allows the control
panel to monitor two phone lines.
panel to monitor two phone lines.
Each D8128D OctoPOPIT combines
eight POPIT points in one module.
eight POPIT points in one module.
D8132 Modules (two 12 VDC, 7Ah batteries)
provide additional power for keypads and
other powered devices.
provide additional power for keypads and
other powered devices.
D8129 OctoRelay provides alarm
and auxiliary relay output.
(Other functions available.)
and auxiliary relay output.
(Other functions available.)
D9210B Modules can be
used for access control.
used for access control.
DX4020 allows communciation
over a Local or Wide Area Network
(LAN/WAN).
over a Local or Wide Area Network
(LAN/WAN).
D8125, D8125INV, or
D8125MUX Interface
used for point expansion.
D8125MUX Interface
used for point expansion.
Table 2:
GV2 Series Control Panel Differences
Features
D9412GV2
D7412GV2
D7212GV2
Access Control
Yes - 8 doors
Yes - 2 doors
No
Arm/Disarm Passcodes
249
99
99
Cards/Tokens
996
396
N/A
Passcode-Protected
Custom Functions
Custom Functions
16
4
4
Number of Printers
3
1
1
Number of Points
246
75
40
Number of Relays
128
64
24
Number of Areas
8
8
4