Sony HDCU-950 User Manual
1-23 (E)
HDCU-950 IMM
A
B
C
D
E
1
2
3
4
5
D107
D106
D105
D101
D108
AT
POWER
H PHASE
REFERENCE
/1.001
90H
REF IN
UN
LOCK
LOCK
HD
REM
BB
BB
STEP
COARSE
ADV
DELAY
POWER
CABLE
ALRAM
OPEN
SHORT
CAM
MAIN
INCOM
MIC-ON
OFF
PGM
PROD
ENG
PRIV
D6
D5
D3
D4
1-7. Functions of Indicators on Boards
1-7-2. AU-281 Board
AU-281 board (panel side)
D3 (green) : MAIN POWER display
Lights up when the power is supplied to the unit correctly.
Lights up when the power is supplied to the unit correctly.
D4 (green) : CAM POWER display
Lights up when DC180 V power is supplied to the con-
nected camera correctly.
Lights up when DC180 V power is supplied to the con-
nected camera correctly.
D5 (red) : CABLE OPEN display
Lights up when OPEN of the power cable using optical/
electrical composite cable is detected.
Blinks when ALARM (attenuation) of the optical level is
detected.
Lights up when OPEN of the power cable using optical/
electrical composite cable is detected.
Blinks when ALARM (attenuation) of the optical level is
detected.
D6 (red) : CABLE SHORT display
Lights up when short-circuit in the power cable using
optical/electrical composite cable.
Lights up when short-circuit in the power cable using
optical/electrical composite cable.
1-7. Functions of Indicators on Boards
1-7-1. AT-149 Board
AT-149 board (A side/panel side)
D101 (green) : Power display
Lights up when the voltage used on this board is normally
supplied.
Lights up when the voltage used on this board is normally
supplied.
D105 (yellow) : 90H display
Lights up when the delay amount of the SD signal for
downconvert is set to 90H.
n
The delay amount is set with S417 on the AT-149 board.
For details, refer to Section 1-6-1. “Setting of Switches on
Boards
Lights up when the delay amount of the SD signal for
downconvert is set to 90H.
n
The delay amount is set with S417 on the AT-149 board.
For details, refer to Section 1-6-1. “Setting of Switches on
Boards
_ AT-149 Board”.
D-106 (green) : /1.001 display
Lights up when the SG operation CLOCK frequency is
74.17582 MHz.
Lights up when the frame frequency coefficient of the HD
signal is set to 1/1.001 times.
n
The frame frequency coefficient is set with S420 on the
AT-149 board. For details, refer to Section 1-6-1. “Setting
of Switches on Boards
Lights up when the SG operation CLOCK frequency is
74.17582 MHz.
Lights up when the frame frequency coefficient of the HD
signal is set to 1/1.001 times.
n
The frame frequency coefficient is set with S420 on the
AT-149 board. For details, refer to Section 1-6-1. “Setting
of Switches on Boards
_ AT-149 Board”.
D107 (green) : REF IN display
Lights up when the REFERENCE signal is input to the
REFERENCE connector on the rear panel.
Lights up when the REFERENCE signal is input to the
REFERENCE connector on the rear panel.
D108 (red) : UNLOCK display
Lights up when the unit cannot be synchronized with the
external REFERENCE signal in the external sync mode.
Lights up when the unit cannot be synchronized with the
external REFERENCE signal in the external sync mode.