Sony HDCU-950 User Manual

Page of 82
2-17 (E)
HDCU-950 IMM
2-5-4. Level Adjustment of the VBS Signal
(only when HKCU-951 is installed)
Adjust the level of the VBS signal output from the unit
using the color bar signal.
Use the switch on the EN-145 board (HKCU-951) and the
control on the panel of the unit for adjustment.
How to adjust using the EN-145 board (HKCU-
951) of the unit
EN-145 board (A side/panel side)
1.
Check the switch S107-3 on the EN-145 board to OFF.
Factory setting : OFF
2.
Press the BARS button of the MSU-700A/750, RCP-
700 series, etc. to display the color bars on the wave-
form or vector monitor.
2-5. Video Signal System
VBS CHROMA control
EN
POWER
LEVEL
SYNC
CHROMA
COMPONENT
VBS
SC PHASE
R/R-Y
G/Y
ADV
DELA
Y
B/B-Y
VBS SYNC control
VBS LEVEL control
GH
J
K
AB
C
1
2
3
4
5
S107
RV201
RV204
1
1
3.
Set the VBS LEVEL and the VBS SYNC control on
the EN-145 board panel to their mechanical center.
Then adjust RV201 (VBS GAIN) and RV204 (SYNC)
in the EN-145 board so that the color bar signal has the
specified amplitude.
Measurement point : VBS OUT connector on the
HDCU rear panel
Specifications :
A = 100 
±1 IRE [for NTSC]
A = 700 
±7 mV p-p [for PAL]
(VBS LEVEL control)
B = 40.0 
±0.4 IRE [for NTSC]
B = 300 
±3 mV p-p [for PAL]
(VBS SYNC control)
Adjust the VBS CHROMA control on the EN-145 board
panel until every spots of the color bar signal fall into the
specified locations “
4” on vectorscope.
R
M
G
B
C
Y
G
Y
L
R
M
G
C
Y
G
Y
L
B
[for NTSC]
[for PAL]
B
[for PAL]
B
[for NTSC]
A
A