Vanguard Heating 000 User Manual

Page of 32
www.desatech.com
113111-01A
9
INSTALLATION
NOTICE: This heater is intended
for use as supplemental heat.
Use this heater along with your
primary heating system. Do not
install this heater as your pri-
mary heat source. If you have a
central heating system, you may
run system’s circulating blower
while using heater. This will help
circulate the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.
 WARNING: A qualified ser-
vice person must install fire-
place. Follow all local codes.
 WARNING: Never install the
fireplace
• in a bedroom or a bathroom
• in a recreational vehicle
• where curtains, furniture,
clothing, or other flammable
objects are less than 36 inches
from the front, top, or sides of
the fireplace
• as a fireplace insert
• in high traffic areas
• in windy or drafty areas
 CAUTION: This fireplace cre-
ates warm air currents. These
currents move heat to wall sur-
faces next to fireplace. Install-
ing fireplace next to vinyl or cloth
wall coverings or operating fire-
place where impurities (such as,
but not limited to, tobacco
smoke, aromatic candles, clean-
ing fluids, oil or kerosene lamps,
etc.) in the air exist, may dis-
color walls or cause odors.
IMPORTANT: 
Vent-free fireplaces add moisture
to the air. Although this is beneficial, installing
fireplace in rooms without enough ventilation air
may cause mildew to form from too much mois-
ture. See Air for Combustion and Ventilation, pages
6 through 8.
Note:
 Your Vanguard fireplace is designed to be
used in zero clearance installations. Wall or fram-
ing material can be placed directly against any
exterior surface of your fireplace, except where
standoff spacers are integrally attached. If stand-
off spacers are attached to your fireplace, these
spacers can be placed directly against wall or fram-
ing materials.
Use the dimensions shown for rough openings to
create the easiest installation (see Built-In Fire-
place Installation
, page 10).
CHECK GAS TYPE
Use only the correct type of gas (natural or pro-
pane/LP). If your gas supply is not the correct gas
type, do not install heater. Call dealer where you
bought heater for proper type heater.
 WARNING: This appliance
is equipped for (natural or pro-
pane/LP) gas. Field conversion
is not permitted.
INSTALLATION ITEMS
Before installing fireplace, make sure you have
the items listed below.
• external regulator - propane/LP only (supplied
by installer)
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• test gauge connection*
• ground joint union
• sediment trap
• tee joint
• pipe wrench
*  A CSA design-certified equipment shutoff valve
with 1/8" NPT tap is an acceptable alternative to
test gauge connection. Purchase the optional CSA
design-certified equipment shutoff valve from your
dealer. See Accessories, page 30.
Note:
 If desired, purchase a four-sided trim kit for
built-in installations. See Accessories, page 30.