Energizer ENCR2P1 618218 Data Sheet

Product codes
618218
Page of 1
Photo
Classification:
"Lithium"
Chemical System:
Lithium / Manganese Dioxide (Li/MnO
2
)
Designation:
IEC-CR2
Nominal Voltage:
3.0 Volts
Storage Temp:
-40°C to 60°C
Operating Temp:
-40°C to 60°C
Typical Capacity:
800 mAh (to 2.0 volts)
(rated at 100 ohms at 21°C)
Typical Weight:
11 grams 
Typical Volume:
5.2 cubic centimeters 
Max Discharge:
1000 mA continuous (2500 mA pulse)
Max Rev Charge:
2 uA
Typical Li Content:
0.28 grams
Shipping: 
For complete details, please reference:
Special Provision A45 of the International
Air Transport Association Dangerous
Goods Regulations
49 CFR 173.185
Type
Drain
Load
2.0V (21°C) 1.8V (21°C) 1.55V (21°C)
(time)
(mA)
(ohms)
(hours)
(pulses)
(pulses)
Capacity
(continuous)
Photoflash
(3 / 27 sec)
Photoflash
(3 / 7 sec)
Photoflash
(3 / 7 sec)
Lithium (CR2)
This battery contains a Positive Temperature 
Coefficient (PTC) safety device to limit current 
during short circuit conditions.
Cutoff Voltage
Industry Standard Dimensions
Global (except US):
Typical Discharge Characteristics
---
United States:
Typical Use Performance 
---
---
---
100
34
Specifications
(millimeters)
Simulated Application Tests
1200
---
---
1140
---
760
---
900
---
This data sheet contains typical information specific to products manufactured at the time of its publication. 
 ©Energizer Holdings, Inc. - Contents herein do not constitute a warranty.
1800
---
Important Notice
---
400
---
1.5
2.0
2.5
3.0
3.5
0
10
20
30
40
V
o
lt
age, C
C
V
Hours
Rated Capacity
100 ohms continuous at 21°C
1.0
1.5
2.0
2.5
3.0
0
150
300
450
600
750
900
V
o
lt
age, C
C
V
Pulses
Photoflash
1200 mA (3 sec on / 7 sec off)
-20 C
21 C
PRODUCT DATASHEET
+ 44 (0) 208 920 2306
www.energizer.eu
15.60
15.10
6.50
Maximum
8.50
0.50
0.05
Contact Recess
27.00
25.80
0.70
Minimum
Minimum
Form No. EBC - 8819EU-B
Page 1 of 1