Suunto HELO2 User Manual

Page of 64
WHEN CEILING AND STOP ARE 
DISPLAYED, MAKE A ONE MINUTE 
MANDATORY SAFETY STOP IN THE 
DEPTH ZONE BETWEEN 6 M AND 3 M.
You must not ascend shallower than 3 m/10 ft with the Mandatory Safety Stop warning
on. If you ascend above the Mandatory Safety Stop ceiling, a downward pointing arrow
will appear and a continuous beeping starts. You should immediately descend to, or below,
the Mandatory Safety Stop ceiling depth. If you correct this situation at any time during
the dive, there are no effects on the decompression calculations for future dives.
WHEN CEILING AND STOP 
ARE DISPLAYED, IMMEDIATELY 
(WITHIN 3 MINUTES) DESCEND 
TO OR BELOW CEILING.
If you continue to violate the Mandatory Safety Stop, the tissue calculation model is affected
and the dive computer shortens the available no-decompression time for your next dive.
In this situation, it is recommended that you prolong your surface interval time before your
next dive.
5.12. Deep stops
The most significant factor limiting the ascent is the ceiling depth. It is the maximum depth
a diver can ascend to before tissue pressures have decreased low enough. In addtion,
separate safety stops are used. Their purpose is to increase the safety margin even if
decreasing the tissue pressures does not require them. Such stops are safety stop when
surfacing and deep stops.
According to UHMS, deep stops are stops that occur deeper than the traditional decom-
pression model suggests. The purpose of deep stops is to slow down a long continuous
ascent and minimize microbubble formation and excitation.
While the Suunto Technical RGBM model is based on M-values, the use of deep stops
brings the model closer to the full RGBM model. The way of implementing deep stops is
conducted by Dr. Bruce Wienke.
If deep stop is broken it does not cause the dive computer to go into error mode. However
there is penalty applied to the following decompressions.
DURING DESCENT, 
YOU ARE SHOWN 
THAT A DEEPSTOP IS 
NEEDED AT THE 
DEPTH OF 25 M.
DURING ASCENT, YOU 
ARE ADVISED TO MAKE A 
DEEPSTOP AT 25 M FOR THE 
DURATION SHOWN BY THE 
TIMER (42 SEC. REMAINING).
26