EMC 300-000-978 REV A03 User Manual

Page of 114
5
5-2
PowerPath Administration on Solaris
PowerPath and CLARiiON Storage Systems
PowerPath events or actions that entail LUN trespasses (for example, 
SP failovers or 
powermt
 
restore
 commands) can cause the Solaris 
disk driver to log warning and/or error messages. You can ignore 
these messages, as PowerPath intercepts them and hides them from 
the application sending the I/O.
For more information on CLARiiON configuration requirements, 
refer to the EMC Installation Roadmap for CX-Series and FC-Series 
Storage Systems
 and the EMC Host Connectivity Guide for Sun Solaris
available on the Powerlink website.
The Host Connectivity Guide describes how to edit the 
/kernel/drv/sd.conf
 file to suppress ODS device overlap error 
messages. Note that this workaround is invalid for Sun Cluster 2.2 
configurations.
Ensuring a Sufficient Stack Size
If you install an application that resets the stack size (for example, 
VxVM or VxFS) after you install PowerPath, make sure that 
lwp_default_stksize
 and 
rpcmod:svc_run_stksize
 are set to at 
least 0x6000 on a Solaris 7, 8, or 9 system, and at least 0x4000 on a 
Solaris 2.6 system. Other applications may reset the stack sizes to 
values insufficient for PowerPath.
Booting a Host With Built-In Fibre Channel Ports
If you boot a Solaris host with all socal host adapters to storage 
system volumes disconnected or dysfunctional, PowerPath will not 
configure any socal host adapter paths. After physically restoring the