Furuno 1712 User Manual

Page of 27
 
 
Caution
Cable clamp
Rotation detector
Shield plate
 
Figure 6 Antenna unit, inside view 
Caution: Be careful not to pinch the 
rotation detector cable when remounting 
the shield plate.   
7.    Pass the antenna cable with connector 
through the gasket and cable clamp, and 
then tighten cable gland. 
Be sure the shrink tubing on the antenna 
cable is not covered by the gasket. 
Rubber gasket
Gasket
Cable Gland
Sectional view
Mounting base
Rubber gasket
 
Figure 7 Antenna unit, inside view 
8.    Referring to Figure 8, fasten the shield 
cable with screw (M4x10) on the chassis to 
ground the unit.   
Connect 9 pin 
connector 
here (J801).
Connect
shield here.
 
Figure 8 How to connect the antenna cable 
to the antenna unit 
9.  Attach EMI Core (supplied) to antenna 
cable. Set the fixing band to the EMI core.   
This bend should be 
facing toward you.
Fixing band
 
Figure 9 Fixing band 
10. Referring to Figure 8, connect the 9-pin 
connector of the antenna cable to J801. 
11. Refasten the shield plate with 10 screws. 
Be sure not to pinch cable from the rotation 
detector with the shield plate. See “Caution” 
in Figure 6 for details. 
12. Fasten the Fixing band with Screw 
(supplied). 
Screw(M4X15)
EMI Core
Fixing 
Band
Align bend with 
corner of chassis.
 
Figure 10 How to fix the EMI Core 
13. Follow the instructions on the label inside 
the mounting base to secure the snap assy. 
14. Confirm that the rubber gasket is properly 
positioned and that the triangle mark on the 
radome cover is aligned with the triangle 
mark on the mounting base, then tighten 
the fixing screws for the cover. Refer to 
Figure 7 for positioning of rubber gasket.