12. Remove the three screws (41) holding the PC Board 
(112) to the meter housing. See F
. 43. Note that 
there is a washer (44) on each screw (41) between 
the board and the meter housing boss.
13. Remove the RF Board (103) from the cover half and 
disconnect the PSM switch cable (H) from the RF 
board (103). Set the old electronics (112, 103) 
aside. See F
. 44 and F
IG
. 46.
14. Connect the new circuit board (112) to the valve 
housing using three screws (41). See F
sure to install a washer (44) on each screw (41) 
between the PC Board and the meter housing boss.
15. Connect the cables/wires (A, B, C, & D) that connect 
the bezel (31) and the valve housing to the circuit 
board (112). See F
When reconnecting cable C to the circuit board 
(112), ensure that the cable is positioned with the white 
tab facing up and that the cable is straight before push-
ing in (closing) the clasp. See F
 
When reconnecting cable D be sure that the wires 
from the valve housing are properly inserted in the valve 
housing wire retainer hook (G). See F
16. Place the meter housing into the new right cover 
half (18) being careful not to dislodge the PSM 
switch (101).
The two ribs (E) of the new meter cover fit between 
the two bolts (F) of the meter housing. Be sure not to 
pinch or crimp the circular switch cable (D) on the new 
cover half. See F
17. Plug connector end of the new PSM switch (101) 
into the RF Board (103). See F
IG
. 46.
F
IG
. 43
C
B
41
41
41
A
D
F
IG
. 44
F
IG
. 45
F
F
E
E
D