Technical Specifications
309497L
35
Technical Specifications
*
Minimum pressure loss at 1.5 gpm (5.7 lpm) with 30-weight oil at 70° F (21° C) is 70 psi.
† At 2.5 gpm (9.5 lpm), at 70° F (21° C) with 10-weight oil, and 1 gallon dispensed. May require calibration.
‡ At 2.5 gpm (9.5 lpm), at 70° F (21° C) with 10-weight oil, and 1 gallon dispensed.
◆Specification based on 30W oil. Lighter viscosity fluid (i.e., anti-freeze) will require a slightly higher inlet fluid 
pressure to open the Matrix valve.
★Using 30W oil at 70°F (21°C). Maximum pressure will be slightly lower with higher viscosity fluids (i.e., gear oil). 
A lower ratio pump may be required to reduce system pressure and maintain sufficient flow.
Maximum Fluid Working Pressure
1500 psi (10.3 MPa, 103 bar)
Operating pressure range (
*
 
◆)
100 to 1500 psi (0.7 to 10.3 MPa) (7 bar to 103 bar)
Maximum Dynamic Working Pressure 
(while dispensing) (
★)
600 psi (4.1 MPa, 41.4 bar)
Flow Range
0.26 to 5 gpm (1 to 18.9 lpm)
Weight (with battery and rigid nozzle extension
4.5 lb (2.0 kg)
Units of measurement
user selectable, pints, quarts, gallons or liters
Maximum recorded dispense volume
999.00 units
Maximum preset volume
900.0
Inlet size
1/2” npt(f)
Outlet size
3/8” npt(f)
Operating temperature range
32° F to 120° F (0° C to 49° C)
Storage temperature range
-30° F to 120° F (-34° C to 49° C)
Battery
rechargeable nickel-metal hydride 9.6 VDC
Battery Warranty
6 months
Battery storage temperature range
50° F to 86° F (10° C to 30° C)
Wetted parts
zinc, stainless steel, carbon steel, polyurethane, nitrile rubber
Fluid compatibility
lubricating oils, antifreeze mixtures
Accuracy (†)
+/- 0.5 percent
Repeatability (‡)
+/- 0.15 percent
RF Communication
902-928 MHz frequency hopping, spread-spectrum - N. A.
915-928 MHz frequency hopping, spread-spectrum - Australia
Unobstructed RF Communication Range (based on 
building construction and RF environment)
300-500 ft. (91.0-152.0 m)
Obstructed RF Communication Range (based on 
building construction and RF environment)
250-300 ft. (76.2-91.0 m)
Approvals (for RF device contained in meter 
246008)
FCC, Industry Canada (IC)
Conformity (for RF device contained in meter 
249881)
ACMA (Australia)