Furuno 1834C-BB User Manual

Page of 86
 
1-2
1.1.2 Mounting procedure 
Flush mounting 
Follow the procedure below to mount the control unit in a panel, using accessories 
FP03-10001. 
 
1.  Prepare a cutout in the mounting location, referring to the outline drawing at the end of 
this manual. 
2.  Set the control unit to the cutout. 
3.  Attach the mounting plate to the control unit with four screws M4 x 10 from the rear side. 
4.  Screw four wing bolts into wing nuts. 
5.  Fasten the control unit to the mounting location with four wing bolts and wing nuts 
assembled at step 4. 
280±1
80±1
(A)
20.5
A: Thickness of panel
10<A<20 mm
 
Flush mounting the control unit 
 
6.  Attach hard cover to protect the control unit. 
How to remove the hard cover
Place your thumbs at the locations shown with 
circles in the illustration at right, and then lift the 
cover while pressing it with your thumbs.