3.2  Checking Magnetron Heater Voltage 
Magnetron heater voltage is formed on the MD (1824C-BB), PTU (1834C-BB) or RTB 
(1934C-BB/1944C-BB/1954C-BB/1964C-BB) Board of the antenna unit, and preadjusted at 
the factory. Therefore, no adjustment is required. However, check magnetron heater voltage 
for confirmation as shown below. This procedure should only be performed by a 
qualified technician.
 
 
1.  Open the antenna unit. 
2.  Turn on the power. Do not transmit the radar. 
3.  Connect a multimeter, set to 10VDC range, appropriate position on the MD (1824C-BB), 
PTU (1834C-BB) or RTB (1934C-BB/1944C-BB/1954C-BB/1964C-BB) Board in the 
antenna unit. Refer to the table in below. 
4.  Confirm that the multimeter indication is within the ratings shown below. 
 
 
MODEL1824C-BB MODEL1834C-BB  MODEL1934C-BB/ 
1944C-BB/1954C-BB/ 
1964C-BB
 
Check point 
TP804#6 (+) and #4 
(-) on MD Board 
TP802#4 (+) and #6 (-) 
on PTU Board 
J825#4 and #6 (GND) on 
RTB Board 
Multimeter 
indication 
7.9 to 8.1 V 
7.4 to 7.6 V 
7.4 to 7.6 V 
Adjustment point 
VR801 on MD Board
R106 on PTU Board 
VR801 on MD Board