Four Wire Connection 
(Preferred to three wire connection)
1. Disconnect electrical power at breaker box.
2. Remove the terminal block cover to expose the
terminal block (See Figure 6).
3. Remove top nut, star washer, and round washer from
each post.
Note: DO NOT remove last round washer, last nut or
internal wiring leads.
4. Remove screw from bottom end of ground strap.
5. Remove ground strap from center post, rotate (so
that wide end is at top) and straighten. Then attach
wide end to range through hole below terminal
block.  Attach green wire on top of ground strap.
Tighten Screw (See Figure 9).
6. Attach red wire, round washer, star washer and nut
IN THIS ORDER to left post (See Figure 10).
7. Attach white wire, round washer, star washer and
nut IN THIS ORDER to center post (See Figure 10).
8. Attach black wire, round washer, star washer and
nut IN THIS ORDER to right post (See Figure 10).
9. Tighten all connections securely and replace
terminal block cover.
10. Properly secure strain relief (see previous page).
Figure 9
Figure 10
Figure 8
Figure 7
Figure 6
Note: DO NOT plug in range at this time.
Proceed to step 7, next page.
Step 6: Installation -  Connect Electric
White
Red
Black
Ground Strap
Green Ground Screw
Ground
Strap
Green
Red
White
Black
Red
White
Black
Ground
Strap
Green Ground Screw
6.  Connect the Range Cord
Three Wire Connection
The Four Wire Connection is preferred, but where local
codes and ordinances permit grounding through neutral,
unit may be connected to the power supply via a three
wire connection.
1. Disconnect electrical power at breaker box.
2. Remove the terminal block cover to expose the
terminal block (See Figure 6).
3. Remove top nut, star washer, and round washer from
each post.
Note: DO NOT remove last round washer, last nut or
internal wiring leads.
4. Attach white wire, round washer, star washer and
nut IN THIS ORDER on top of ground strap  on center
post.  DO NOT remove ground strap. (See Figure 7).
5. Attach red wire, round washer, star washer and nut
IN THIS ORDER to left post (See Figure 7).
6. Attach black wire, round washer, star washer and
nut IN THIS ORDER to right post (See Figure 7).
7. Tighten all connections securely and replace