Instructions for the installer 
 
7
 
3  INSTALLATION OF THE APPLIANCE 
 
 
It is the law that all gas appliances are installed by 
authorised persons. Clearance around 
the cooker must comply with the requirements of  AS5601.
 
 
3.1  Electrical connection 
Make sure that the power line voltage matches the specifications indicated on the rating plate located 
inside the storage compartment.  
This rating plate must never be removed. 
 
 
On the power line, install a two-pole cut-off device with contact cut-off distance greater than or equal to 
3 mm, located in an easily accessible position near the unit. 
 
 
 
 
The wire section on the cable must not be less than 1.5 
mm
2
 (3 x 1.5 cable), keeping in mind that the end to be 
connected to the cooker must have the ground wire 
(yellow-green) longer by at least 20 mm. Use only the 
special cables available at our Service Centres. 
 
 
 
The manufacturer declines all responsibility for damage to persons or things caused by non-
observance of the above prescriptions or by interference with any part of the appliance. 
 
 
 
Overall dimensions: location of gas and electrical connection points (all measures in mm). 
 
 
 
 
A
B
C
D
900
750
 
100 
 
660 
 
160 
 
220