Installation Instructions 
  
  
     
  
 
 
   
 
  
  
    
  
 
  
 
BEFORE YOU BEGIN 
 
 
CAUTION: 
  
Read these instructions completely and 
carefully. 
 
THESE RANGES SHOULD BE INSTALLED IN 
CONJUNCTION WITH A SUITABLE 
OVERHEAD VENT HOOD. Due to the high heat 
  
  
 
capacity of this unit, particular attention should be paid to the hood 
• 
IMPORTANT
 
-
 Save these instructions for local
 
 
duct work installation to assure it meets local building codes. 
inspector's use. 
 
 
  
  
 
  
  
• 
IMPORTANT
 
Observe all governing codes and
 
  Standard countertop installations: 
ordinances. 
 
A 1200 CFM hood is recommended for 48" & 60" ranges. 
  
  
 
A 600 CFM hood is recommended for 30" & 36" ranges. 
• 
Note to Installer
 - 
Be sure to leave these instructions
 
    
  
with the Consumer. 
 
Hoods should be 24" min. deep and at least the same width as the  
  
  
 
cooktop. FiveStar hoods may be installed from 24” to 30” above the 
• 
Note to Consumer
 - 
Keep these instructions for future
 
 
cooking surface. A minimum of 28” is required when a FiveStar
 
reference. 
 
Backsplash with warming shelves is used. 
  
  
 
 
• 
FiveStar recommends this product be installed by a
 
 
Check local building codes for the proper method of gas range 
licensed professional. 
 
installation. Local codes vary. Installation, electrical connections and 
  
  
 
grounding must comply with applicable codes. In the absence of local 
• 
Product failure due to improper installation is not covered
 
 
codes, the gas range should be installed in accordance with the 
under the Warranty. 
 
National Fuel Gas Code ANSI 223.1, latest edition and National 
  
  
 
Electrical Code ANSI/NFPA 70, latest edition.
 
 
  
 
WARNING: 
 
  
 
  
This appliance must be properly grounded. 
 
 
 
  
  
 
 
CAUTION:
 
In the Commonwealth of Massachusetts: 
 
 
These ranges weigh up to 510 pounds. Some 
• 
This product must be installed by a licensed plumber or 
gas
 
 
disassembly will reduce the weight considerable. Due to 
fitter. 
 
the weight and size of the range and to reduce the risk of 
  
  
 
personal injury or damage to the produce and/or damage 
• 
When using ball type gas shut-off valves, they shall be T
 
 
to the floor, TWO PEOPLE ARE REQUIRE FOR PROPER 
handle type. 
 
INSTALLATION.
  
  
  
  
    
  
• 
A flexible gas connector, when used, must not exceed
 
   
 
Three (3) feet.