Force10 C300 8-slot chassis w/ backplane CH-C300 Leaflet

Product codes
CH-C300
Page of 2
© 2009 Force10 Networks, Inc. All rights reserved. Force10 Networks, Adit, 
E-Series, Traverse, and TraverseEdge are registered trademarks and Axxius,
C-Series, ExaScale, FTOS, MASTERseries, P-Series, S-Series, TeraScale, and
TransAccess are trademarks of Force10 Networks, Inc. All other company names
are trademarks of their respective holders. Information in this document is subject
to change without notice. Certain features may not yet be generally available.
Force10 Networks, Inc. assumes no responsibility for any errors that may appear 
in this document.
CSDS02   
809   v3.4
Force10 Networks, Inc.
350 Holger Way
San Jose, CA 95134 USA
www.force10networks.com
408-571-3500
PHONE
408-571-3550
FACSIMILE
Chassis
C300 – 8 line card slots
2 Route processor module with integrated switch fabric slots
8 Power supply module slots and 1 fan tray slot
Size: 13 RU, 22.7 h x 17.4 w x 14.4" d (57.66 h x 44.2 w x 37.58 cm d)
Weight with factory-installed components: 55 lbs (24.95 kg)
Weight fully loaded: 152.27 lbs (69.07 kg)
ISO 7779 A-weighted sound pressure level: 73.8 dBA at 73.4°F (23°C)
AC power
Nominal input voltage:
100–240 VAC 50/60 Hz
Maximum thermal output:
4,978 BTU/h (1,498 W) at 100/120 VAC
4,864 BTU/h (1,459 W) at 200/220 VAC
Maximum input current per module:
14 A at 100 VAC, 12 A at 120 VAC, 7 A at 200 VAC, 6 A at 240 VAC
Maximum system power input:
8.7 KVA at 100/120 VAC, 8.5 KVA at 200/240 VAC
Maximum power consumption:
8,675 W at 100/120 VAC, 8,476 W at 200/240 VAC
DC power
Nominal input voltage: 
–44 to –55 VDC
Maximum thermal output:
4,231 BTU/h (1,240 W)
Maximum current draw per DC PEM:
32 A
Maximum power consumption:
1,460 W
C150 – 4  line card slots
2 Route processor module with integrated switch fabric slots
6 Power supply module slots and 1 fan tray slot
Size: 9 RU, 15.7 h x 17.5 w x 15.3" d (39.88 h x 44.45 w x 38.86 cm d)
Weight with factory-installed components: 38 lbs (17.24 kg)
Weight fully loaded: 86.63 lbs (39.29 kg)
ISO 7779 A-weighted sound pressure level: 69.3 dBA at 73.4°F (23°C)
AC power
Nominal input voltage:
100–240 VAC 50/60 Hz
Maximum thermal output:
2,891 BTU/h (862 W) at 100/120 VAC
2,824 BTU/h (840 W) at 200/220 VAC
Maximum input current per module:
14 A at 100 VAC, 12 A at 120 VAC, 7 A at 200 VAC, 6 A at 240 VAC
Maximum system power input:
4.5 KVA at 100/120 VAC, 4.4 KVA at 200/240 VAC
Maximum power consumption:
4,420 W at 100/120 VAC, 4,319 W at 200/240 VAC
DC power
Nominal input voltage:
–44 to –55 VDC
Maximum thermal output: 
2,457 BTU/h (720 W)
Maximum current draw per DC PEM: 
32 A
Maximum power consumption: 
800 W
Common
19" front rack mountable
Maximum operating specifications:
Temperature: 32° to 104°F (0° to 40°C)
Altitude: no performance degradation to 10,000 feet (3,048 meters)
Relative humidity: 5 to 85% (RH), non-condensing
Maximum non-operating specifications:
Temperature: -40° to 158°F (-40° to 70°C)
Maximum altitude: 15,000 feet (4,572 meters)
Relative humidity: 5 to 95% (RH), non-condensing
Redundancy/Availability
1+1 redundant Switch Fabric & Route Processor Modules (RPM)
C300: 2+1 redundant system AC Power Supply Modules
1+1 redundant system DC Power Entry Modules
4+1 redundant PoE Power Supply Modules supporting up to 
384 PoE ports at 15.4 W with deterministic failure mode
C150: 1+1 redundant system AC Power Supply Modules
1+1 redundant system DC Power Entry Modules
2+2 redundant PoE Power Supply Modules supporting up to 
192 PoE ports at 15.4 W with deterministic failure mode
Online insertion and removal of all components
Environmental self-monitoring
Performance
MAC addresses: 
C150: 256K, C300: 512K
IPv4 routes: 
12K
IPv6 routes: 
6K
Switching fabric capacity: 
C150: 768 Gbps (476 Mpps)  
C300: 1,536 Tbps (952 Mpps)
Link aggregation: 
8 links per group, 128 groups per chassis
Queues per port: 
4 queues
VLANs: 
1024 VLANs with 4096 tag value support
Line-rate Layer 2 switching: all protocols, including IPv4 and IPv6
Line-rate Layer 3 routing: 
IPv4 and IPv6
LAG load balancing: 
based on Layer 2, IPv4 or IPv6 headers
Switching latency: 
<5 µs for 64 byte frames
IEEE Compliance
802.1AB LLDP
802.1D
Bridging, STP
802.1p
L2 Prioritization
802.1Q
VLAN Tagging, Double VLAN Tagging, GVRP
802.1s
MSTP
802.1w
RSTP
802.1X
Network Access Control
802.3ab
Gigabit Ethernet (1000BASE-T)
802.3ac
Frame Extensions for VLAN Tagging
802.3ad
Link Aggregation with LACP
802.3ae
10 Gigabit Ethernet (10GBASE-X)
802.3af
Power over Ethernet
802.3ak
10 Gigabit Ethernet (10GBASE-CX4)
802.3i
Ethernet (10BASE-T)
802.3u
Fast Ethernet (100BASE-FX, 100BASE-TX)
802.3x
Flow Control
802.3z
Gigabit Ethernet (1000BASE-X)
ANSI/TIA-1057      LLDP-MED
Force10
FRRP (Force10 Redundant Ring Protocol)
Force10
PVST+
MTU
9,252 bytes
RFC and I-D Compliance
General Internet Protocols
768
UDP
793
TCP
854
Telnet
959
FTP
1321 MD5
General IPv4 Protocols
791
IPv4
792
ICMP
826
ARP
1027 Proxy ARP
1035 DNS (client)
1042 Ethernet Transmission
1191 Path MTU Discovery
1305 NTPv3
1519 CIDR
1542 BOOTP (relay)
General IPv6 Protocols
1981 Path MTU Discovery (partial)
2460 IPv6
2461 Neighbor Discovery (partial)
2462 Stateless Address 
Autoconfiguration (partial)
2463 ICMPv6
RIP
1058 RIPv1
OSPF
1587 NSSA
2154 MD5
2328 OSPFv2
2370 Opaque LSA
BGP
1997 Communities
2385 MD5
2439 Route Flap Damping
2545 Multiprotocol Extensions 
for IPv6
2796 Route Reflection
2842 Capabilities
draft-ietf-idr-bgp4-20  BGPv4
draft-ietf-idr-restart-06  Graceful Restart
Multicast
1112 IGMPv1
2236 IGMPv2
3376 IGMPv3
3569 SSM for IPv4
Network Management
1155 SMIv1
1156 Internet MIB
1157 SNMPv1
1212 Concise MIB Definitions
1215 SNMP Traps
1493 Bridges MIB
1850 OSPFv2 MIB
1901 Community-based 
SNMPv2
2011 IP MIB
2012 TCP MIB
2013 UDP MIB
2024 DLSw MIB
2096 IP Forwarding Table MIB
2570 SNMPv3
2571 Management Frameworks
2572 Message Processing and 
Dispatching
2574 SNMPv3 USM
2575 SNMPv3 VACM
2576 Coexistence Between 
SNMPv1/v2/v3
2578 SMIv2
2579 Textual Conventions for 
SMIv2
2580 Conformance Statements 
for SMIv2
2618 RADIUS Authentication MIB
2665 Ethernet-like Interfaces MIB
2674 Extended Bridge MIB
2787 VRRP MIB
2819 RMON MIB 
(groups 1, 2, 3, 9)
2863 Interfaces MIB
Regulatory Compliance
Safety
UL/CSA 60950-1, 1st Edition
EN 60950-1, 1st Edition
IEC 60950-1, 1st Edition Including all National Deviations 
and Group Differences
EN 60825-1 Safety of Laser Products Part 1: 
Equipment Classification Requirements and User's Guide
EN 60825-2 Safety of Laser Products Part 2: 
Safety of Optical Fibre Communication Systems
FDA Regulation 21 CFR 1040.10 and 1040.11
Emissions
Australia/New Zealand: AS/NZS CISPR 22: 2006, Class A
Canada: ICES-003, Issue-4, Class A
Europe: EN 55022: 2006 (CISPR 22: 2006), Class A
Japan: VCCI V3/2007.04 Class A
USA: FCC CFR 47 Part 15, Subpart B, Class A
Immunity
EN 300 386 V1.3.3: 2005 EMC for Network Equipment
EN 55024: 1998 + A1: 2001 + A2: 2003
EN 61000-3-2: Harmonic Current Emissions
EN 61000-3-3:Voltage Fluctuations and Flicker
EN 61000-4-2: ESD
EN 61000-4-3: Radiated Immunity
EN 61000-4-4: EFT
EN 61000-4-5: Surge
EN 61000-4-6: Low Frequency Conducted Immunity
RoHS
All C-Series components are EU RoHS compliant.
Ordering Information
O
RDER
N
UMBER
D
ESCRIPTION
CH-C150
C150 4-slot chassis with backplane
CH-C300
C300 8-slot chassis with backplane
CC-C150-FAN2 
C150 enhanced fan subsystem
CC-C300-FAN2
C300 enhanced fan subsystem
LC-CB-RPM
Switch Fabric and Route Processor 
Module (series CB)
LC-CB-10GE-4P
4-port 10 Gigabit Ethernet line card, 
XFP modules required (series CB)
LC-CB-10GE-8P
8-port 10 Gigabit Ethernet line card, 
XFP modules required (series CB)
LC-CB-GE-48P
48-port Gigabit Ethernet line card, 
SFP modules required (series CB)
LC-CB-GE-48T
48-port 10/100/1000Base-T line card 
with RJ45 interfaces (series CB)
LC-CB-GE-48V
48-port 10/100/1000Base-T line card 
with RJ45 interfaces and PoE (series CB)
LC-CB-10G-1G-36T
FlexMedia line card with 36 
10/100/1000Base-T RJ45 interfaces, 
eight GbE interfaces – SFP modules 
required, and two 10 GbE interfaces – 
SFP+ modules required (series CB)
LC-CB-10G-1G-36V
FlexMedia line card with 36 
10/100/1000Base-T RJ45 interfaces with 
PoE, eight GbE interfaces – SFP modules
required, and two 10 GbE interfaces – 
SFP+ modules required (series CB)
CC-C-1200W-AC
1200 W AC Power Supply Module
CC-C-PWR-DC
1400 W DC Power Entry Module
SW-CB-LATEST
FTOS software
Specifications: 
C-Series Resilient Switches 
1350
TFTP
2474
Differentiated Services
3164
Syslog
draft-ietf-bfd-base-03
BFD
2858 Multiprotocol Extensions
2918
Route Refresh
3065
Confederations
4360
Extended Communities
4893
4-byte ASN
5396
4-byte ASN Representation
4541 IGMPv1/v2 
Snooping
draft-ietf-pim-sm-v2-new-05  
PIM-SM for IPv4
2865 RADIUS
3273 RMON High Capacity MIB
3376 IGMPv3
3416 SNMPv2
3418 SNMP MIB
3434 RMON High Capacity 
Alarm MIB
3580 802.1X with RADIUS
5060 PIM MIB
ANSI/TIA-1057
LLDP-MED MIB
draft-grant-tacacs-02
TACACS+
draft-ietf-idr-bgp4-mib-06
BGP MIBv1
IEEE 802.1AB
LLDP MIB, LLDP DOT1
MIB, LLDP DOT3 MIB
ruzin-mstp-mib-02
MSTP MIB (traps)
sFlow.org sFlowv5
sFlow.org sFlowv5 MIB 
(version 1.3)
FORCE10-BGP4-V2-MIB
FORCE10-CS-CHASSIS-MIB
FORCE10-IF-EXTENSION-MIB
FORCE10-LINKAGG-MIB
FORCE10-COPY-CONFIG-MIB
FORCE10-MON-MIB
FORCE10-PRODUCTS-MIB
FORCE10-SMI
FORCE10-SYSTEM-COMPONENT-MIB
FORCE10-TC-MIB
FORCE10-TRAP-ALARM-MIB
1812
Routers
1858
IP Fragment Filtering
2131
DHCP (server and relay)
2338
VRRP
3021
31-bit Prefixes
3046
DHCP Option 82
3069
Private VLAN
3128
Tiny Fragment Attack 
Protection
2464 Ethernet Transmission
2675 Jumbograms
3587 Global Unicast Address 
Format
4291 Addressing
2453
RIPv2
2740
OSPFv3
3623
Graceful Restart
4222
Prioritization and 
Congestion Avoidance