COOKER HOOD INSTALLATION 
 
The bottom of the hood should be 25 
1/2
" (65 cm) min. to 31 
1/2
" (80 cm) above the countertop. This would 
typically result in the bottom of the hood being 61 
1/2
" (156.2 cm) to 67 
1/2
" (171.5 cm) above the floor. Check 
for other minimum clearance requirements mandated by specific local or regional installation codes. Refer to 
the rangehood installation instructions for additional information. These dimensions provide for safe and 
efficient operation of the hood. 
 
ELECTRICAL CONNECTION 
This unit is manufactured for a polarized, grounded 120 VAC/60 Hz, 15A  3 pin-earthed receptacle. Electric 
power consumption is about 150 W. The minimum of 102 VAC is required for proper operation of gas ignition 
systems. This circuit must be grounded and properly polarized. The unit is equipped witth a SJT power cord. 
In case of replacement, the cable shall be replaced with one of the same type, size and length. 
 
WARNING
 
 
Cooling fan failure. 
In case of a cooling fan failure the frontal red indicator "Fan Failure" will light up. If this happens, please turn 
off the appliance immediately, call the nearest after sale assistance service center and do not use the 
appliance until the cooling fan system of the appliance has been properly repaired by a qualified technician. 
 
WARNING
 
 
Electrical Grounding Instructions  
This appliance is equipped with a three-prong plug for your protection against shock hazard and should be 
plugged directly into a properly grounded socket. Do not cut or remove the grounding prong from this plug. 
 
WARNING 
ELECTRICAL SHOCK HAZARD 
•  Disconnect electrical power at the circuit breaker box or fuse box before installing the gas cooker 
•  Electrically ground gas cooker 
• 
Use copper conductors only. Failure to follow these instructions could resul in serious injury or death