Carrier 30XW150-400 User Manual

Page of 148
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Catalog No. 04-53300024-01
Printed in U.S.A.
Form 30XW-1T
Pg 1
11-09
Replaces: New
Controls, Start-Up, Operation, Service 
and Troubleshooting
CONTENTS
Page
SAFETY CONSIDERATIONS
. . . . . . . . . . . . . . . . . . . . . . 2
GENERAL
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3-9
Conventions Used in This Manual
. . . . . . . . . . . . . . . . 3
Display Module Usage
 . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
• TOUCH PILOT™ DISPLAY
• NAVIGATOR™ DISPLAY MODULE
CONTROLS
 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  9-18
General
 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Main Base Board (MBB)
. . . . . . . . . . . . . . . . . . . . . . . . . . 9
Compressor Protection Module (CPM)
 . . . . . . . . . . 10
Electronic Expansion Valve (EXV) Board
 . . . . . . . . 13
MLV/Condenser Board
 . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Enable-Off-Remote Contact Switch (SW1)
. . . . . . . 16
Emergency On/Off Switch (SW2)
 . . . . . . . . . . . . . . . . 16
Energy Management Module (EMM)
. . . . . . . . . . . . . 16
Local Equipment Network
. . . . . . . . . . . . . . . . . . . . . . . 17
Board Addresses
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Touch Pilot Display
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Control Module Communication
. . . . . . . . . . . . . . . . . 17
• RED  LED
• GREEN LED
• YELLOW LED
Carrier Comfort Network
®
 (CCN) Interface
. . . . . . . 18
Remote Alarm and Alert Relays
 . . . . . . . . . . . . . . . . . 18
CONFIGURATION
 . . . . . . . . . . . . . . . . . . . . . . . . . . . .  18-46
Touch Pilot Operation Configuration Tables
. . . . . 18
Machine Control Methods
. . . . . . . . . . . . . . . . . . . . . . . 20
Machine On/Off Control
 . . . . . . . . . . . . . . . . . . . . . . . . . 20
• TOUCH PILOT MACHINE CONTROL
• NAVIGATOR DISPLAY MACHINE CONTROL
Entering Fluid Control Option
. . . . . . . . . . . . . . . . . . . 25
Cooling Set Point Selection
 . . . . . . . . . . . . . . . . . . . . . 25
• SET POINT OCCUPANCY
Chilled Water Fluid Type Selection
 . . . . . . . . . . . . . . 27
• FRESH WATER
• BRINE OR GLYCOL OPERATION
Cooler Pump Control
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
• COOLER PUMP CONTROL CONFIRGURATIONS
Machine Start Delay
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Circuit/Compressor Staging and Loading
 . . . . . . . 29
• CIRCUIT/COMPRESSOR STAGING
• CIRCUIT/COMPRESSOR LOADING
Minimum Load Control
. . . . . . . . . . . . . . . . . . . . . . . . . . 29
Dual Chiller Control
 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
• DUAL CHILLER CONTROL FOR PARALLEL 
APPLICATIONS
• DUAL CHILLER PUMP CONTROL FOR PARALLEL 
CHILLER APPLICATIONS
• DUAL CHILLER CONTROL FOR SERIES 
APPLICATIONS
• DUAL CHILLER PUMP CONTROL FOR SERIES 
CHILLER APPLICATIONS
Page
Ramp Loading
 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Temperature Reset
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
• RETURN WATER RESET
• SPACE TEMPERATURE RESET
• 4-20 mA TEMPERATURE RESET
Demand Limit
 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
• SWITCH CONTROLLED DEMAND LIMIT
• EXTERNALLY POWERED CAPACITY BASED 
DEMAND LIMIT
• EXTERNALLY POWERED CURRENT BASED 
DEMAND LIMIT
• CCN LOADSHED CONTROLLED DEMAND LIMIT
Ice Storage Operation
. . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Broadcast Configuration
 . . . . . . . . . . . . . . . . . . . . . . . . 41
• ACTIVATE
• BROADCAST ACKNOWLEDGER
Alarm Control
 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
• ALARM ROUTING CONTROL
• ALARM EQUIPMENT PRIORITY
• COMMUNICATION FAILURE RETRY TIME
• RE-ALARM TIME
• ALARM SYSTEM NAME
Daylight Saving Time Configuration
. . . . . . . . . . . . . 43
Capacity Control Overrides
 . . . . . . . . . . . . . . . . . . . . . 43
Head Pressure Control
. . . . . . . . . . . . . . . . . . . . . . . . . . 46
• LOW CONDENSER FLUID TEMPERATURE HEAD 
PRESSURE CONTROL OPTION
PRE-START-UP
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46,47
System Check
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
START-UP
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  47-53
Actual Start-Up
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Operating Limitations
. . . . . . . . . . . . . . . . . . . . . . . . . . . 47
• TEMPERATURES
• VOLTAGE
• MINIMUM FLUID LOOP VOLUME
• FLOW RATE REQUIREMENTS
OPERATION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  54-59
Sequence of Operation
. . . . . . . . . . . . . . . . . . . . . . . . . . 54
Dual Chiller Sequence of Operation
. . . . . . . . . . . . . 54
• PUMP  OPERATION
Operating Modes
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Sensors
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
• THERMISTORS
• TRANSDUCERS
SERVICE
 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  59-67
Economizer Assembly
 . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Electronic Expansion Valve (EXV)
. . . . . . . . . . . . . . . 59
• MAIN EXV CONTROL
• ECONOMIZER EXV CONTROL
• EXV TROUBLESHOOTING PROCEDURE
Compressor Assembly
. . . . . . . . . . . . . . . . . . . . . . . . . . 63
• COMPRESSOR OIL SYSTEM
AQUAFORCE
®
30XW150-400
Water-Cooled Liquid Chillers