Specifications
 
3M™ Dynatel™ Advanced Modular System 965AMS
General Specifications
Drop test
Survives 3 ft (1 m) drop onto concrete, (survives 5 ft drop onto 
concrete with soft case) using ASTM D4169 assurance level I 
method 5276 
Vibration
Meets Mil 810F method 514.5
Water, dust and chemical proof
Meets IP65 per IEC 529(1989) for rain and dust
Immersion test IP67 0.15 m deep
Emissions
Standards meet FCC part 15, class A: Digital Devices for the US, 
and EN55022 (radiated emissions) 
Built to ISO9001/2000 certification 
for manufacturing facilities and TL 
9000 compliant
Built to ANSI/IPC A610-C 
manufacturing standards 
Language
English, Spanish, and French Canadian
Units
Feet or meters, Fahrenheit or Celsius, dBrnC or dBm0p, m/uS or Vp
Battery
Rechargeable battery pack or alkaline, 
9 hours typical use (50% on/off measures voltage) 
Display
4.1” x 3.1”(104 x 79 mm), 320 x 240 pixel resolution,  
high visibility in bright sunlight
Operating temperature
0° to 140°F (-18 to 60°C)
Storage temperature
-40° to 165°F (-40 to 75°C)
Moisture: rain, water and humidity 
proof
Meets or exceeds IP65, IP67
Note: Routine lab calibration is not recommended or required